(11) CUSTOMIZE THE APPLICATION SETTINGS
2. DIFFERENTIALS
Determines the temperature above/below the temperature setting at which the heating or cooling equipment will turn
3. Use the ▲ or ▼ button to highlight “SET DIFFERENTIAL” |
and press the SELECT button. |
– If the thermostat SINGLE/MULTI dip switch is set for |
1. PROGRAMMABLE OR NON-PROGRAMMABLE
This thermostat can be configured as a programmable or
| This setting is best for homeowners where there |
| are regularly scheduled, long periods of time |
| during any day where the house is not occupied, |
| such as when everyone is at school or work. In |
| the program, there will be four scheduled |
| temperature changes per day (events) labeled |
| Wake, Leave, Return and Sleep. |
This setting is best for homeowners who have | |
| no long periods of time during the day when the |
| home is unoccupied. In the program, there will |
| be only two scheduled temperature changes per |
| day (events) labeled Day and Night. |
| This setting is best for businesses that are |
| occupied during business hours and not occupied |
| during |
| will be only two scheduled temperature changes |
| per day (events) labeled Occupied and Unoccupied. |
1.Make sure the thermostat is in the OFF mode.
2.Press MENU button to show the MAIN MENU.
3.Scroll down through the menu items and select SETTINGS.
4.In the SETTINGS MENU, scroll down through the menu items and select EVENTS PER DAY.
5.To cancel, press the BACK button. This will return you to the
SETTINGS MENU.
6.To change, use the ▲ or ▼ button to scroll to the desired setting.
7.To finish and return to the SETTINGS MENU, press the SELECT button.
on. For example, a heat temperature setting of 70°F with a differential of 2° will result in the equipment turning on and off to maintain the temperature between 68°F and 70°F. If the second stage differential is also 2°, the second stage would be used to ensure the temperature did not drop below 66°. The default setting for the first stage and second stage differential is 1°.
To change the differential settings:
1.Make sure the thermostat is in the OFF mode.
2.Press and hold both the ▲ and ▼ buttons for 3 seconds.
– The display will show the ADV. SETTINGS MENU.
| MULTI, two differentials will appear, if set for SINGLE, |
| only one will appear. |
4. | To cancel, press the BACK button. This will return you |
| to the ADV. SETTINGS MENU. |
5. | To change the first stage differential, press the ▲ and ▼ |
| button to raise or lower the setting. To change the second |
| stage differential, press the SELECT button. |
6. | To finish and return to the ADV. SETTINGS MENU, press |
| the SELECT button after the value(s) have been set. |
| – For heat pumps – the auxiliary heat differential(s) are |
| set separately after the number of auxiliary heat stages is |
| selected. See Diagrams |
| heat set up instructions. |
- 36 - | - 37 - |