Aprilaire installation instructions Safety Instructions, Model 8570 Specifications

Page 3

SAFETY INSTRUCTIONS

Read this Installation Manual before beginning installation of the Aprilaire® 8570 Thermostat. For questions call Research Products Corporation at (800) 334-6011.

WARNING

1.120 Volts may cause serious injury from electrical shock. Disconnect electrical power to the HVAC equipment before starting installation. This thermostat is not a 120-volt (line voltage) device.

2.Improper installation may cause serious injury from electrical shock. This product must be installed by a qualified heating and air conditioning contractor in accordance with NEC Standards and applicable local and state codes.

3.Mercury is toxic and may be hazardous to health. Any replaced thermostats containing mercury must be disposed of properly. Contact local authorities for disposal information.

MODEL 8570 SPECIFICATIONS

Electrical

Thermostat Voltage:

24-volts ± 20% AC or DC

Total Load Current:

5A

Single Output Load Current:

2A

Thermal

Operating Range:

32°F – 99°F (0 C – 37 C)

Display Accuracy:

±1°F between 60°F and 80°F, ±2°F outside this range

Control Accuracy:

±1°F

Control Range Heat:

40°F – 88°F (4 C – 30 C)

Control Range Cool:

42°F – 90°F (6 C – 32 C)

Heat/Cool Deadband:

Adjustable 2° or 5° F or C

1st Stage Differential:

Adjustable 1°F – 4°F (1°F default)

2nd Stage Differential:

Adjustable 1°F – 4°F (1°F default)

Temperature Offset:

Adjustable 1°F – 4°F

- 1 -

Image 3
Contents Safety & Installation Instructions Table of Contents Model 8570 Specifications Safety InstructionsWire Requirements Mount the Thermostat Base to the Wall Open the ThermostatSingle Multi Elect GAS Set to HP when installed with heat pumpsRun a cable with the correct number of wires Wire the Thermostat to the Hvac EquipmentAprilaire Model Diagram 4 Boiler with AC Diagram 7 Single-Stage Heat Pump with Two-Stage Optional Wire the Event Triggered Output ETO Turn it off when unoccupiedLoad Or West Side Settings MenuProgrammable Output NORTH, East85.4 230.6163.8 117.6Thermostat Mount the Adhc and its outdoor temperature sensorMount the indoor temperature sensor Thermostat Startup Stand Alone Applications Control SET UPThermostat SET UP SET Number of Auxiliary Heat Stages Auxiliary Heat SetupCheck FAN Operation Check Heating Operation Multi Check Cooling OperationThermostat does not call for cooling To Cool and make a call for coolingGas To Emergency Heat and make a call for heatSingle/Multi Same outputs come on Regardless of how these are setCustomize the Application Settings Offset ADV. Settings Menu Range is -10F to 35F and OFFTo go back a character, press the Back button Press the Menu button Press the Call Dealer button Press the Reset buttonBOX 1467 MADISON,WI
Related manuals