Gianni Industries AD-425S Opening, closing and maintain -open time illustration table

Page 6

The opening, closing and maintain -open time illustration table.

VM

 

Opening and

 

Total Opening and

TC Time

Maintain -open

 

 

 

(Opening and

 

Closing

 

Closing Time (VM+

(Maintain -open

time

Closing Time

 

Operating

 

Brake Time)

time adjustment)

(See Figure 4)

Adjustment )

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

4.5

 

 

1

 

 

 

 

 

 

 

 

 

 

3

 

6.0

 

 

5

 

 

 

 

 

 

 

 

 

 

5

 

8.0

 

 

10

 

 

 

 

 

 

 

 

 

 

7

 

9.5

 

 

15

 

 

 

 

 

 

 

 

 

 

2

 

 

4.5 (With high torque

 

20

 

 

 

output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

6.0 (With high torque

 

25

 

 

 

output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

8.0 (With high torque

 

 

30

 

 

 

 

output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

9.5 (With high torque

 

 

35

 

 

 

 

output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zFor the wider door leaf, we suggest that you can extend the opening and closing time or adjust the high torque output. For the 95cm~120cm door width, please refer the gray region for setting. The high torque output enhanced the door stability.

zThe opening operation based on 90° angle; however, there would be time difference from the setting angles.

zPlease refer to the below table for TC settings.

Door width

 

 

Door weight (kg)

 

 

 

 

 

 

 

 

(cm)

50 kg

60 kg

70 kg

80 kg

90 kg

100 kg

 

 

 

 

 

 

 

 

75 cm

20 s

20 s

22 s

22 s

25 s

28 s

 

 

 

 

 

 

 

85 cm

20 s

20 s

22 s

22 s

25 s

28 s

 

 

 

 

 

 

 

100 cm

22 s

22 s

24 s

24 s

27 s

30 s

 

 

 

 

 

 

 

120 cm

22 s

22 s

24 s

24 s

27 s

30 s

 

 

 

 

 

 

 

Copyright All Rights Reserved.

 

P-MU-AD425S Ver. A Publish:2008.07.11

Page: 6/ 20

Image 6
Contents General Safety Precautions AD-425S Automatic Door OperatorSecurity Statement Manufacturers DeclarationAll Packing materials Construction NameControl Board Control Board Guide MotorBattery Opening, closing and maintain -open time illustration table Specification Current See FigureInstallation instructions Prepare the installationPage Page AD-425S Template Installation Instruction Installation Steps Out-swing door Right-Hand Open Steps Steps Steps Need a Stopper Ball Steps Trouble shooting LockMaintenance every 6 months Normal OperationDistributor