Hearth and Home Technologies SANTAFEI-B Santa Fe Pellet Insert Thermostat Installation, Left Side

Page 23

R

Santa Fe Pellet Insert

J. Thermostat Installation

1. A 12 volt AC thermostat is required to operate this pellet appliance. You may use the included wall mount thermo- stat or purchase an optional programmable thermostat or remote control.

The included thermostat is equipped with an adjustable heat anticipator. The current rating is .05 amps. The anticipator needs to be adjusted to the lowest setting available.

2.When mounting a thermostat on a wall, be sure to follow your thermostat installation instructions carefully.

NOTE: Thermostat must be mounted level for accu- rate readings. The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air. Remove any packaging from inside the thermostat before using.

NOTE: If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired tem- perature in your home.

3.There is a 4 screw terminal block located on the junction box to the right of the power cord inlet. The center 2 screws are for the thermostat wires. The outer 2 are the mounting screws for the terminal block. Figure 23.1.

 

Cut Away

 

 

 

 

 

LEFT SIDE

 

 

 

unction Box

 

unction Box, Front

 

Power

Red Call

Fuse

110 Outlet for

Cord

Light

 

Remote

Recepticle

 

 

Control Only

Terminal Block

 

(unfused)

 

 

Center 2 Screws

 

 

for Thermostat

 

 

Wires or Remote

 

 

CAUTION

Shock hazard.

Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appli- ance.

Figure 23.1

CAUTION

The 110 outlet on the junction box is for a remote control ONLY. Do not use outlet for any other purpose. It can damage the appliance and it will void your warranty.

September 1, 2008

7019-205C

Page 23

Image 23
Contents Hot glass will cause burns Santa FE Pellet InsertSanta Fe Pellet Insert Behind left access panelLocation On chain behind right access panel Table of Contents Glass Specifications Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifications Mobile Home ApprovedAppliance Location Design, Installation & Location ConsiderationsGetting Started Negative Pressure Santa Fe Pellet Insert Locating Your Appliance & ChimneyDraft Inspect Appliance & Components and Pre-Use Check List Santa Fe Pellet Insert Fire SafetyTools And Supplies Needed Appliance Dimensions 3Dimensions and ClearancesShown with Rear Vent and Optional Outside Air Santa Fe Pellet Insert Clearance To Combustibles, UL and ULCMantel De 12 inc Floor ProtectionMinimum Opening for Masonry and Zero Clearance Fireplaces Starter hole Mark area of floor to cut Venting Termination Requirements 4Vent InformationChimney and Exhaust Connection Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartSanta Fe Pellet Insert Equivalent Feet of Pipe 5Venting Systems Side panel removed Santa Fe Pellet Insert Full Reline With Outside AirSide view of Santa Fe Insert with 6Mobile Home Mobile Home InstallationOutside Air Kit Instructions 7Appliance Set-UpLeveling System Grille Bracket Cover Door Removal Door Trim InstallationDoor Handle Removal Size 9d x 45w, 2 to 10 Height Adjustment Santa Fe Pellet Insert Adjustable Hearth SupportCompleted View Santa Fe Pellet Insert Panel and Trim SetOptional Firepot Top Log Installation Four Piece Log Set InstallationLeft Side Santa Fe Pellet Insert Thermostat InstallationGeneral Operating Information Operating InstructionsFuel Size And Material Starting Your First Fire Fire CharacteristicsFeed Rate Adjustment Instructions Santa Fe Pellet Insert Before Your First FireSanta Fe Pellet Insert Ignition Cycles Frequently Asked QuestionsPossible Cause Corrective Action 9TroubleshootingSymptom Page Symptom Possible Cause Corrective Action Types of Fuel Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Frequency Daily Weekly Monthly YearlyDisposal of Ashes Frequency As needed Cleaning Firepot with Cleaning Rod & Firepot Clean-Out ToolCleaning Ash Drawer See .1 on Ash Removal from FireboxDoor Latch Inspection Cleaning Beneath Heat ExchangerPreparing Firebox for Non-Burn Season Cleaning the HopperCleaning Exhaust Blower Requires No Lubrication Cleaning Convection Blower Requires No LubricationArning Santa Fe Pellet Insert High Ash Fuel Content MaintenanceConvection Blower Replacement Santa Fe Pellet Insert Blower ReplacementCombustion Exhaust Blower Replacement Santa Fe Pellet Insert Igniter Replacement Glass Replacement Santa Fe Pellet Insert Baffle & Brick Set Removal Re-installing Baffle & Brick SetHook on left side Tab on right side Component Function Reference MaterialsSnap Disc #2 Fuel Delivery Interrupt 250F Vacuum SwitchWiring Harnes See .1 below Snap Disc #1 Convection Blower 110FComponent Locations Right Side Cleaning Rods & Heat Exchanger TubesDescription Part Number Santa Fe Pellet Insert Exploded ViewsSanta Fe Pellet Insert Item No Service Parts, Alphabetical Order Santa Fe Pellet Insert Service Parts and AccessoriesSCRAPER-SFI Santa Fe Pellet Insert, Black Grilles Item No Accessories, Alphabetical OrderItem No Appliance Date of Service Performed By Description of Service Santa Fe Pellet Insert Service And Maintenance LogSanta Fe Pellet Insert Service And Maintenance Log Cont’d Santa Fe Pellet Insert Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability Santa Fe Pellet Insert Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d T O T O

SANTAFEI-B specifications

Hearth and Home Technologies SANTAFEI-B is a standout fireplace option renowned for its intelligent design, efficiency, and ease of use. This innovative fireplace blends modern technology with classic aesthetic appeal, making it a popular choice for homeowners seeking ambiance and functionality.

One of the standout features of the SANTAFEI-B is its high-efficiency design. With an efficiency rating that significantly exceeds traditional fireplaces, this model maximizes heat output while minimizing fuel consumption. This efficiency not only translates into lower heating bills but also means that the energy used is effectively converted into warmth for your living space.

The SANTAFEI-B incorporates advanced technology such as the IntelliFireā„¢ ignition system, which offers easy start-up and reliable operation. This technology simplifies the process of lighting the fire and maintaining it, allowing users to enjoy a warm and inviting atmosphere with minimal effort. Additionally, the system is equipped with remote control options for enhanced convenience, enabling users to adjust the flames and heat from the comfort of their seat.

Design-wise, the SANTAFEI-B is available in various styles and finishes, ensuring it can seamlessly fit into any home decor. The customizable options allow homeowners to express their personal style, whether they prefer a sleek modern look or a more traditional aesthetic. The large viewing area provides a stunning display of the flames, creating an inviting focal point in any room.

Moreover, the fireplace is fitted with a variety of safety features that make it a reliable choice for families. These features include safety screens and automatic shut-off mechanisms that ensure peace of mind when using this appliance.

In terms of maintenance, the SANTAFEI-B is designed for easy cleaning and upkeep. Durable materials are used in its construction, which not only enhances its longevity but also makes it simple to maintain its appearance.

In summary, Hearth and Home Technologies SANTAFEI-B is a sophisticated fireplace that combines efficiency, modern technology, and stylish design. With features designed for safety and convenience, it stands out as an excellent choice for anyone looking to enhance their home with a beautiful and functional heating solution. The SANTAFEI-B truly represents the best of both worlds, marrying warmth and comfort with contemporary living.