LG Electronics LA090HPO, LA120HPO, LA120CPO, LA120HPI, LA120CPI Product Specifications, Models

Page 11

Product Specifications

Product Specifications

 

Models

 

 

AS-C091F2G0(LA091CNP)

AS-C121F2G0(LA121CNP)

AS-H091F2G0(LA091HNP)

AS-H121F2G0(LA121HNP)

 

 

 

AS-C091F2G0(LA090CP)

AS-C121F2G0(LA120CP)

AS-H091F2G0(LA090HP)

AS-H121F2G0(LA120HP)

 

 

 

 

 

 

Cooling Capacity

 

 

 

 

kW

2.87

3.37

2.87

3.37

(Min~Rating~Max)

 

 

 

 

Btu/h

9,800

11,500

9,800

11,500

Heating Capacity

 

 

 

 

kW

-

-

2.87

3.37

(Min~Rating~Max)

 

 

 

 

Btu/h

-

-

9,800

11,500

Power Input

Cooling/Heating

 

 

 

W

980

1,100

980/980

1,100/1,100

Running Current

Cooling/Heating

 

 

 

A

9.4

10

9.4/9.4

10/10

Starting Current

Cooling/Heating

 

 

 

A

57.0

57.0

57.0/57.0

57.0/57.0

EER

 

 

 

 

W/W

2.93

3.06

2.93

3.06

 

 

 

 

Btu/h.W

10.0

10.5

10.0

10.5

 

 

 

 

 

COP

 

 

 

 

W/W

-

-

2.93

3.06

Power Supply

 

 

 

 

Ø / V / Hz

1/115/60

1/115/60

1/115/60

1/115/60

Power Factor

 

 

 

%

90.7

95.7

90.7

95.7

Air Flow Rate

Indoor,Max

 

 

m3/min(cfm)

9.3(330)

9.3(330)

9.3(330)

9.3(330)

Outdoor,Max

 

 

m3/min(cfm)

25(883)

25(883)

25(883)

25(883)

Moisture Removal

 

 

 

 

l/h

1.4

1.4

1.4

1.4

Sound Level

Indoor,H/M/L

 

 

 

dB(A)+3

41/35/29

41/35/29

41/35/29

41/35/29

Outdoor,Max

 

 

 

dB(A)+3

48

48

48

48

 

 

 

 

Refrigerant & Charge(at

7.5m)

 

 

 

g(oz)

R410A, 900(31.8)

R410A, 900(31.8)

R410A, 900(31.8)

R410A, 900(31.8)

 

Type

 

 

Rotary

Rotary

Rotary

Rotary

Compressor

Model

 

 

GK113CAA

GK113CAA

GK113CAA

GK113CAA

Motor Type

 

 

PSC

PSC

PSC

PSC

 

 

 

 

Oil Type

 

 

FVC68D(PVE)

FVC68D(PVE)

FVC68D(PVE)

FVC68D(PVE)

 

Oil Charge

 

 

cc

330

330

330

330

 

O.L.P Name

 

 

MRA12053-12027

MRA12053-12027

MRA12053-12027

MRA12053-12027

Fan(Indoor)

Type

 

 

Turbo Fan

Turbo Fan

Turbo Fan

Turbo Fan

Motor Output

 

 

W

24

24

24

24

 

 

 

Fan(outdoor)

Type

 

 

Propeller

Propeller

Propeller

Propeller

Motor Type

 

 

AC Induction

AC Induction

AC Induction

AC Induction

 

Motor Output

 

 

W

27

27

27

27

Circuit Breaker*

 

 

 

 

A

20

20

20

20

Power Supply Cable

 

 

 

 

No.*mm2

3*2.5

3*2.5

3*2.5

3*2.5

Power and Transmission Cable

 

No.*mm2+No.mm2

4*0.75

4*0.75

4*0.75

4*0.75

Piping

Liquid Side

 

 

mm(in)

6.35(1/4)

6.35(1/4)

6.35(1/4)

6.35(1/4)

Connections

Gas Side

 

 

mm(in)

12.7(1/2)

12.7(1/2)

12.7(1/2)

12.7(1/2)

Drain Hose

O.D , I.D

 

 

mm(in)

21.5,16(0.85,0.63)

21.5,16(0.85,0.63)

21.5,16(0.85,0.63)

21.5,16(0.85,0.63)

 

Indoor(W*H*D)

 

 

 

mm

600*600*146

600*600*146

600*600*146

600*600*146

Dimension

 

 

 

inch

23.62*23.62*5.75

23.62*23.62*5.75

23.62*23.62*5.75

23.62*23.62*5.75

 

 

 

 

Outdoor(W*H*D)

 

 

 

mm

770*540*245

770*540*245

770*540*245

770*540*245

 

 

 

 

 

 

 

 

inch

30.31*21.26*9.65

30.31*21.26*9.65

30.31*21.26*9.65

30.31*21.26*9.65

 

 

 

 

 

Net Weight

Indoor

 

 

kg(lbs)

15(33.1)

15(33.1)

15(33.1)

15(33.1)

Outdoor

 

 

 

kg(lbs)

32(70.5)

32(70.5)

32(70.5)

32(70.5)

 

 

 

Tool Code(Chassis)

Indoor + Outdoor

 

 

SF + UL

SF + UL

SF + UL

SF + UL

Functions

Temperature Control

 

 

Thermistor

Thermistor

Thermistor

Thermistor

Plasma Filter

 

 

O

O

O

O

 

Prefilter(washable/anti-fungus)

O

O

O

O

 

Auto Clean

 

 

O

O

O

O

 

CHAOS Wind(Auto Wind)

O

O

O

O

 

Steps, Fan/Cool/Heat

3/4

3/4

3/4/3

3/4/3

 

Airflow Direction Control(up&down)

Auto

Auto

Auto

Auto

 

Airflow Direction Control(left&right)

Auto

Auto

Auto

Auto

 

Remocon Type

 

 

Wireless LCD

Wireless LCD

Wireless LCD

Wireless LCD

 

Setting Temperature

 

Cooling

18 ~ 30

18 ~ 30

18 ~ 30

18 ~ 30

 

Range

 

Heating

-

-

16 ~ 30

16 ~ 30

 

Auto Operation (Micom Control)

O

O

O

O

 

Auto Changeover (Micom Control)

O

O

O

O

 

Self Diagnosis

 

 

O

O

O

O

 

Timer

 

 

24h, On/Off

24h, On/Off

24h, On/Off

24h, On/Off

 

Sleep Operation

 

 

O

O

O

O

 

Soft Dry Operation

 

 

O

O

O

O

 

Restart Delay(minute)

3

3

3

3

 

Deice Control(Defrost)

-

-

O

O

 

Hot Start

 

 

-

-

O

O

 

Jet Cool

 

 

O

O

O

O

 

Low Ambient Operation

-

-

-

-

 

Special Function

 

 

-

-

-

-

Network Functions

Dry Contact

 

 

-

-

-

-

Network Solution(LGAP)

-

-

-

-

 

 

PI485

 

 

-

-

-

-

Note:

O : Applied, - : No relation

* For circuit breaker rating, please conform to local standards wherever necessary.

Some of functions are slightly different depending upon models.

The specification may be subject to change without notic for purpose of improvement.

Service Manual 11

Image 11
Contents Room Air Conditioner Table of Contents Install the panel and the cover Safety PrecautionsInstallation Do not use damaged power cords, plugs, or a loose socketOperation Do not install the product on a defective installation standSounds, odors, or smoke comes When flammable gas leaks, turnDo not place a heater or other Do not use the product in a tightThat water is drained away prop Keep level even when installingIng foods, works of art, etc. It is a Product when removingDo not use the product for spe Cial purposes, such as preservIt is not sanitary and could cause DisuseOutlet while the air conditioner is Indoor Unit DimensionsSymbols Used in this Manual 9k, 12k Models Outdoor UnitModels Product SpecificationsInstallation Tools InstallationInstallation Parts Installation Map This Product Contains R-410A Refrigerant Confirm The RefrigerantOutdoor unit Rooftop InstallationsSelect the best Location Indoor unitPiping Length and Elevation Oil trap should be installed every 16.4~23feets 5~7 metersDrain hose junction Preparing Work for InstallationOpen panel front Cover pipe and cover side removeCase of nothing wrong, connect Pipe and the wire. Refer to installationFixing Indoor Unit Flaring Work Flaring work and connection of pipingFoamed polyethylene or equivalent is recommended Connecting the PipingCheck IndoorIndoor unit tubing Flare nut Pipings Wrap the insulation material around the connecting portionBad case For right piping. Follow the instruction below Good caseConnection of Piping -Outdoor Connecting the Cables How to connect wiring to the terminals Connection method of the connecting cableExampleConnecting the cable between indoor unit and outdoor unit Drain piping Checking the DrainageTo check the drainage Forming the Piping Air purging with vacuum pump Air PurgingAir purging Finishing the job Soap water methodEvacuation Charging Panel Front Assembly Evaluation of the performance Prepare remote controllerTest Running Settlement of outdoor unitPump Down Pump Down ProcedureHow to replace picture & photograph Functions OperationFunction of main control Time delay Safety ControlChaos Swing Mode Cooling Operation ModeAuto Operation for Cooling Auto Operation Electronic control modeAuto Operation for Heatingonly Heating Model Healthy DehumidificationAuto Operation for Dehumidificationonly Heating Model Hot-Start Control Heating Operation Modeonly Heating ModelHeating Mode with the Sleep Modeonly Heating Model Cooling or Heating Mode with Sleep Mode Auto ControlCooling Mode with the Sleep Mode Test operation Auto restartForced Operation Cooling Heat pump ModelOperation Indication Lamps Signal ReceptorDisplay Function Self-diagnosis FunctionNd F Button Remote Control OperationsControls To remove the Control Box DisassemblyTo remove the Grille from the Chassis To remove the Motor To remove the Evaporator. Remove hole tubing holdeBefore removing the Turbo Fan Heat Pump/Cooling Only SeriesIndoor Unit Schematic DiagramHeat Pump Series/ Cooling Only Series Outdoor Unit No A20999A PCB ASSEMBLY, Main Top View Bottom View Indoor Unit P.W.B. AssemblyNo A20901C PCB ASSEMBLY, Main Top View Bottom View Outdoor Unit P.W.B. AssemblyDisplay P.W.B. ASM No A20921A PCB AssemblyWiring Diagram Outdoor UnitCooling Only Models, & Heating Models Refrigeration Cycle Diagram Troubleshooting GuidePiping Length and Elevation Air purging of the charge hose ProcedureWay Valve Pumping DownRe-air purging Gas leakage Balance refrigerant of the 3-way valveAll amount of refrigerant leaked EvacuationPurge the air from the charge hose Gas ChargingAfter Evacuation Connect the charge hose to the charging cylinderAdditional gas charging Method of using graphMethod of using equation According to Indoor & Outdoor TemperatureTrouble analysis Cycle PartsProduct does not operate at all Electronic Parts 9k modelProduct is not operate with the remote controller Compressor/Outdoor Fan are unable to drive Nector When indoor Fan does not operateWhen Vertical Louver does not operate When a comunication error occurs Indoor Unit Phenomena in case of connecting errorOutdoor Unit RY-COMP-B Voltage of Connectors according to Indoor Fan SpeedIndoor Unit Exploded ViewOutdoor Unit Parts ListIndoor Replacement Parts ListParts ListOutdoor December No A20926C