LG Electronics LA120HPO, LA090HPO, LA120CPO, LA120HPI, LA120CPI service manual Parts ListOutdoor

Page 75

Replacement Parts List

Parts List(Outdoor)

LOCATION

 

 

PART No.

 

 

DESCRIPTION

 

 

 

 

REMARKS

No.

LAU091CNP

LAU091HNP

LAU121CNP

LAU121HNP

 

 

LA090CPO

LA090HPO

LA120CPO

LA120HPO

 

 

 

(ASUC091FUG0)

(ASUH091FUG0)

(ASUC121FUG0)

(ASUH121FUG0)

 

430410

Base Assembly,Outdoor

3041A20008K

3041A20008K

3041A20008K

3041A20008K

-

 

 

 

 

 

 

 

552203-1

Valve,Service

5220A20006A

5220A20006A

5220A20006A

5220A20006A

Gas Pipe

 

 

 

 

 

 

 

552203-2

Valve,Service

5220A20005B

5220A20005B

5220A20005B

5220A20005B

Liquid Pipe

 

 

 

 

 

 

 

554031

Condenser Assembly,Bending

5403A20019M

5403A20019M

5403A20019M

5403A20019M

-

 

 

 

 

 

 

 

549610

Bracket Assembly,Motor(Outdoor)

4961A10015D

4961A10015D

4961A10015D

4961A10015D

-

 

 

 

 

 

 

 

346811

AC Motor Assembly

4681A20122B

4681A20122B

4681A20122B

4681A20122B

-

 

 

 

 

 

 

 

559010

Fan Assembly,Propeller

5901A10033A

5901A10033A

5901A10033A

5901A10033A

-

 

 

 

 

 

 

 

447910

Barrier Assembly,Outdoor

4791A30002U

4791A30002U

4791A30002U

4791A30002U

-

 

 

 

 

 

 

 

550140

Damper,Compressor

4H00982E

4H00982E

4H00982E

4H00982E

-

 

 

 

 

 

 

 

554160

Compressor Set,Korea

2520UGAC2AA

2520UGAC2AA

2520UGAC2AA

2520UGAC2AA

-

 

 

 

 

 

 

 

567502

Overload Protect

6750U-L029A

6750U-L029A

6750U-L029A

6750U-L029A

-

 

 

 

 

 

 

 

552113

Tube Assembly,Condenser(Out)

5211A24118C

5211A24118C

5211A24118C

5211A24118C

-

 

 

 

 

 

 

 

552116

Tube Assembly,Reverse

5211A26008B

5211A26008B

5211A26008B

5211A26008B

-

 

 

 

 

 

 

 

552202

Valve,Reverse

5220AR3228D

5220AR3228D

5220AR3228D

5220AR3228D

-

 

 

 

 

 

 

 

566000

Switch,Pressure

6600L000013

6600L000013

6600L000013

6600L000013

-

 

 

 

 

 

 

 

561410

Solenoid

-

6141A90007C

-

6141A90007C

Only H/P Model

 

 

 

 

 

 

 

649950

Case Assembly,Control(Outdoor)

4995A21006S

4995A21006S

4995A21006S

4995A21006S

-

 

 

 

 

 

 

 

268711-6

PCB Assembly

6871A20901C

6871A20901C

6871A20901C

6871A20901C

Outdoor PCB

 

 

 

 

 

 

 

567480-4

Thermistor,NTC

6323A20002L

6323A20002L

6323A20002L

6323A20002L

Inlet-air+Cond. out

 

 

 

 

 

 

 

567480-6

Thermistor,NTC

6323A20016A

6323A20016A

6323A20016A

6323A20016A

Suction Pipe Temp.

 

 

 

 

 

 

 

W0CZZ

Capacitor,Film,Box

6120AR2359U

6120AR2359U

6120AR2359U

6120AR2359U

-

 

 

 

 

 

 

 

437212

Panel Assembly,Rear(Outdoor)

3721A20026M

3721A20026M

3721A20026M

3721A20026M

-

 

 

 

 

 

 

 

437211

Panel Assembly,Front(Outdoor)

3721A20027Q

3721A20027Q

3721A20027Q

3721A20027Q

-

 

 

 

 

 

 

 

435301

Grille,Discharge

3530A20006G

3530A20006G

3530A20006G

3530A20006G

-

 

 

 

 

 

 

 

435511

Cover Assembly,Control(Outdoor)

3551AR7184R

3551AR7184R

3551AR7184R

3551AR7184R

REAR PANEL

 

 

 

 

 

 

 

NOTE) *Please ensure GCSC since the replacement parts may be changed demending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List)on GCSC.

(GCSC Website http://biz.Lgservice.com)

Service Manual 75

Image 75
Contents Room Air Conditioner Table of Contents Install the panel and the cover Safety PrecautionsInstallation Do not use damaged power cords, plugs, or a loose socketOperation Do not install the product on a defective installation standSounds, odors, or smoke comes When flammable gas leaks, turnDo not place a heater or other Do not use the product in a tightThat water is drained away prop Keep level even when installingIng foods, works of art, etc. It is a Product when removingDo not use the product for spe Cial purposes, such as preservDisuse Outlet while the air conditioner isIt is not sanitary and could cause Dimensions Symbols Used in this ManualIndoor Unit 9k, 12k Models Outdoor UnitModels Product SpecificationsInstallation Installation PartsInstallation Tools Installation Map This Product Contains R-410A Refrigerant Confirm The RefrigerantOutdoor unit Rooftop InstallationsSelect the best Location Indoor unitPiping Length and Elevation Oil trap should be installed every 16.4~23feets 5~7 metersDrain hose junction Preparing Work for InstallationOpen panel front Cover pipe and cover side removePipe and the wire. Refer to installation Fixing Indoor UnitCase of nothing wrong, connect Flaring Work Flaring work and connection of pipingFoamed polyethylene or equivalent is recommended Connecting the PipingCheck IndoorIndoor unit tubing Flare nut Pipings Wrap the insulation material around the connecting portionBad case For right piping. Follow the instruction below Good caseConnection of Piping -Outdoor Connecting the Cables How to connect wiring to the terminals Connection method of the connecting cableExampleConnecting the cable between indoor unit and outdoor unit Checking the Drainage To check the drainageDrain piping Forming the Piping Air Purging Air purgingAir purging with vacuum pump Soap water method EvacuationFinishing the job Charging Panel Front Assembly Evaluation of the performance Prepare remote controllerTest Running Settlement of outdoor unitPump Down Pump Down ProcedureHow to replace picture & photograph Functions OperationFunction of main control Time delay Safety ControlChaos Swing Mode Cooling Operation ModeAuto Operation for Cooling Auto Operation Electronic control modeHealthy Dehumidification Auto Operation for Dehumidificationonly Heating ModelAuto Operation for Heatingonly Heating Model Hot-Start Control Heating Operation Modeonly Heating ModelCooling or Heating Mode with Sleep Mode Auto Control Cooling Mode with the Sleep ModeHeating Mode with the Sleep Modeonly Heating Model Test operation Auto restartForced Operation Cooling Heat pump ModelOperation Indication Lamps Signal ReceptorDisplay Function Self-diagnosis FunctionRemote Control Operations ControlsNd F Button Disassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Evaporator. Remove hole tubing holde Before removing the Turbo FanTo remove the Motor Heat Pump/Cooling Only SeriesIndoor Unit Schematic DiagramHeat Pump Series/ Cooling Only Series Outdoor Unit No A20999A PCB ASSEMBLY, Main Top View Bottom View Indoor Unit P.W.B. AssemblyNo A20901C PCB ASSEMBLY, Main Top View Bottom View Outdoor Unit P.W.B. AssemblyDisplay P.W.B. ASM No A20921A PCB AssemblyWiring Diagram Outdoor UnitCooling Only Models, & Heating Models Refrigeration Cycle Diagram Troubleshooting GuidePiping Length and Elevation Air purging of the charge hose ProcedureWay Valve Pumping DownRe-air purging Gas leakage Balance refrigerant of the 3-way valveAll amount of refrigerant leaked EvacuationPurge the air from the charge hose Gas ChargingAfter Evacuation Connect the charge hose to the charging cylinderAdditional gas charging Method of using graphMethod of using equation According to Indoor & Outdoor TemperatureTrouble analysis Cycle PartsProduct does not operate at all Electronic Parts 9k modelProduct is not operate with the remote controller Compressor/Outdoor Fan are unable to drive Nector When indoor Fan does not operateWhen Vertical Louver does not operate When a comunication error occurs Indoor Unit Phenomena in case of connecting errorOutdoor Unit RY-COMP-B Voltage of Connectors according to Indoor Fan SpeedIndoor Unit Exploded ViewOutdoor Unit Parts ListIndoor Replacement Parts ListParts ListOutdoor December No A20926C