Operation
Operation
Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
•Room temperature sensor (THERMISTOR)
Room temperature control
•Maintains the room temperature in accordance with the Setting Temp.
Starting Current Control
•Indoor fan is delayed for 5 seconds at the starting.
Time Delay Safety Control
•Restarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
• High, Med, Low and Auto
Operation indication Lamps (LED)
Healthy Dehumidification Mode
• Intermittent operation of fan at low speed
Sleep Mode Auto Control
•The fan is switched to low(Cooling), med(Heating) speed.
•The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Auto Air Control by the unit electronic control
•The fan is switched to intermittent or irregular operation.
•The fan speed is automatically switched from high to low speed.
Chaos Swing
•The louver can be set at the desired position or swing up and down automatically.
Defrost control(Heating)
•Both the indoor and outdoor fan stops during defrosting.
•Hot start will be operated after defrosting ends.
•The indoor fan stops until the indoor pipe temperature will be reached at 82°F(28°C).
36Room Air Conditioner