LG Electronics LT1030CR owner manual Installation Requirements

Page 11

Installation

Installation

Remove packing materials from the wall sleeve and tape from the air conditioner.

INSTALLATION REQUIREMENTS

If you use an existing wall sleeve, you should measure its dimensions.

Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner. (FIG. 1)

With the LGE sleeve(optionally supplied with your unit), you can maintain the best performance of the new air conditioner. (FIG. 2)

20-3/32"

(511 mm)

24"(610 mm)

14-13/32" (366 mm)

 

18-15/32"(468 mm)

Air Conditioner

FIG. 1

INSTALLATION HARDWARE

1

2

4

 

5

 

 

 

2 Size options

8

 

6

 

10

9

3

 

 

 

7

 

2 Size options

ITEM

NAME OF PARTS

Q'TY

1

PLASTIC GRILLE

1

2

VERTICAL INSULATION STRIP

1

3

AROUND INSULATION STRIPS

2

4

HORIZONTAL INSULATION STRIP

1

5

SUPPORT BLOCK

2

6

BAFFLE

1

7

TRIM FRAME

2

8

SHIM

2

9

PLASTIC NUTS AND WASHER SCREWS

4

 

 

 

ENGLISH

Aluminum metal grille

LGE Wall Sleeve

25-7/8"

(656 mm)

15-17/32"

(394 mm)

16-23/32"

(425 mm)

FIG. 2

To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

• Air conditioners covered in this manual pose an

excessive weight hazard. Two or more people are

needed to move and install the unit.

To prevent injury or strain, use proper lifting and

carrying techniques when moving unit.

• Carefully inspect location where air conditioner will

be installed. Be sure it will support the weight of

the unit over an extended period of time.

ELECTRICAL SERVICE

Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).

All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SAVE CARTON for storage and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.

• Handle air conditioner with care. Wear protective

gloves whenever lifting or carrying the unit. AVOID

the sharp metal fins of front and rear coils.

• Make sure air conditioner does not fall during

installation.

REQUIRED TOOLS:

• Tight Fitting gloves

3/8-inch open end

• Standard screwdriver

wrench or adjustable

wrench

• Phillips screwdriver

1/4-inch hex socket

• Pliers

and ratchet

• Sharp knife

• Tape measure

 

 

• Electric drill

 

1/4-inch drill bit

Owner’s Manual 11

Image 11
Contents Room AIR Conditioner Table of Contents Be caution when unpacking and installing Safety PrecautionsDon’t use a power cord, a Always plug into a grounded Outlet Power cord length Is damagedVentilate the room well when Unplug the unit if strangeSounds, odors, or smoke Come from it During operationIt will cause electric shock or fire Hold the plug by the head When gas leaks, openKeep level parallel in installing the product Otherwise, it may cause vibration or water leakageBe cautious not to touch Sharp edges when Perform ventilation Installing SometimesDo not block the inlet or outlet of air flow Do not step on Always insert the filterPreparing for Operation Cleaning and MaintenanceService Before Operation Introduction Symbols Used in this Manual Features Wash hands after handling Electrical SafetyUse Wall Receptacle Power Supply Electrical DataPlease Read Carefully Electrical SafetyInstallation Requirements InstallationHOW to Install InstallationTo the wall sleeve. If you need plastic nuts to Procedure aInstall the new unit into the wall sleeve Supplied with your unit,skip to stepFasten the screws Procedure BTop View Wall Procedure aRemove the backing from the support blocks Procedure CRemove the backing from the Horizontal Remove the backing from the 1113/16 shim To achieve rearward slope for unit drainingControls Operating InstructionsFAN Fan-only operation Remote controlIncrements of 1 F Air Direction How to insert BatteriesVentilation How to Attach Front Grille to Cabinet Maintenance and ServiceAir Filter Cleaning Normal Operation Common Problems and SolutionsTroubleshooting Memo Nombre del distribuidor Fecha de compra Escriba aquí el modelo y número de serieModelo n Serie n Aparato Precauciones de SeguridadToma a tierra No desmonte ni modifique Tenga cuidado al Los productosNo ponga el cable de alimentación cerca de un calentador Mantenga nivelado el producto al instalarlo No dañe ni use un enchufe de alimentación no especificadoSostenga el enchufe por su cabeza al sacarlo Puntiagudos al instalar Ocasiones Del aire durante el No se suba a la unidad Inserte siempre el filtroServicio Preparación para el funcionamientoUso Limpieza y mantenimientoCaracterísticas IntroducciónSímbolos Utilizados en Este Manual Datos Electricos Seguraida ElectricaImportante Favorlea CON Atención Seguraida ElectricaFrontal y posterior InstalacionRequisitos DE Instalación Período de tiempoCómo Instalar InstalaciónPared Procedimiento aApriete los tornillos Procedimiento BPerspectiva superior Coloque la rejilla plásticaProcedimiento a Ajuste la posición según describe el pasoIgual a 18, salte al paso 7. Si no, corte las Procedimiento CDrenaje de la unidad, retire el envoltorio de las Del soporte de paredDel ventilador, control de temperatura en 72 F Instruccionnes de FuncionamientoControles El ajuste se muestra en pantallaEl ajuste aparece en pantalla Control remotoReinicio automático Incrementos de 1 FDirección del aire Cómo Poner Las BateriasVentilación Como agregar la rejilla frontal al gabinete Cuidado y MantenimientoLimpieza del filtro de aire Gire el control de Temperatura a un número más bajo Problemas y soluciones habitualesOperación normal Operación anormalNota Nota Aire Acondicionador Garantía Limitada DEL Aire Acondicionador LG EE.UU Patent No. Us 6, 412 No A21004Q LG Room AIR Conditioner Limited Warranty USA