LG Electronics LT1030CR owner manual Procedure B, Top View, Fasten the screws

Page 14

Installation

PROCEDURE B

1 Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the FIG 8. The use of pliers is recommended.

 

7 3/32"

60°

60°

 

Rear Louvers

 

(Top View)

 

FIG. 8

2

If the wall sleeve already has a rear grille, skip

 

to step 4. If the wall sleeve does not have a rear

grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

4

Remove the backing from the Vertical Insulation

 

strip 159/16 x 13/8 x 13/8 and attach that to the

inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside front of the sleeve as shown below.

Indoor

Outdoor

Around Insulation

 

Vertical Insulation

 

9 1/2"

6"

 

FIG. 11

Place the plastic grille

FIG. 9

 

 

3

Fasten the 4 washer screws to secure the grille

 

to the wall sleeve. If you need plastic nuts to

5 If the depth of your existing wall sleeve is less than or equal to 18", skip to step 6. Otherwise, cut the baffles and the support blocks according to length "A" in the table below.

mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.

 

or

Fasten the screws

FIG. 10

 

Depth"D" of the existing

Length "A"

wall sleeve (inches)

(inches)

 

 

 

18 D

18-5/8

3/4

18-5/8

D 19-3/4

1-3/4

19-3/4

D 22

4

 

 

 

A

Support

Block

Baffle

A FIG. 12

14Room Air Conditioner

Image 14
Contents Room AIR Conditioner Table of Contents Outlet Power cord length Is damaged Safety PrecautionsDon’t use a power cord, a Always plug into a grounded Be caution when unpacking and installingCome from it During operation Unplug the unit if strangeSounds, odors, or smoke Ventilate the room well whenOtherwise, it may cause vibration or water leakage Hold the plug by the head When gas leaks, openKeep level parallel in installing the product It will cause electric shock or fireDo not step on Always insert the filter Sharp edges when Perform ventilation Installing SometimesDo not block the inlet or outlet of air flow Be cautious not to touchBefore Operation Cleaning and MaintenanceService Preparing for OperationIntroduction Symbols Used in this ManualFeatures Electrical Data Electrical SafetyUse Wall Receptacle Power Supply Wash hands after handlingElectrical Safety Please Read CarefullyInstallation Installation RequirementsInstallation HOW to InstallSupplied with your unit,skip to step Procedure aInstall the new unit into the wall sleeve To the wall sleeve. If you need plastic nuts toFasten the screws Procedure BTop View Procedure a WallRemove the backing from the support blocks Procedure CRemove the backing from the Horizontal To achieve rearward slope for unit draining Remove the backing from the 1113/16 shimOperating Instructions ControlsFAN Fan-only operation Remote controlIncrements of 1 F Air Direction How to insert BatteriesVentilation How to Attach Front Grille to Cabinet Maintenance and ServiceAir Filter Cleaning Normal Operation Common Problems and SolutionsTroubleshooting Memo Nombre del distribuidor Fecha de compra Escriba aquí el modelo y número de serieModelo n Serie n No desmonte ni modifique Tenga cuidado al Los productos Precauciones de SeguridadToma a tierra AparatoNo ponga el cable de alimentación cerca de un calentador Mantenga nivelado el producto al instalarlo No dañe ni use un enchufe de alimentación no especificadoSostenga el enchufe por su cabeza al sacarlo No se suba a la unidad Inserte siempre el filtro Puntiagudos al instalar Ocasiones Del aire durante elLimpieza y mantenimiento Preparación para el funcionamientoUso ServicioCaracterísticas IntroducciónSímbolos Utilizados en Este Manual Seguraida Electrica Datos ElectricosSeguraida Electrica Importante Favorlea CON AtenciónPeríodo de tiempo InstalacionRequisitos DE Instalación Frontal y posteriorInstalación Cómo InstalarProcedimiento a ParedColoque la rejilla plástica Procedimiento BPerspectiva superior Apriete los tornillosAjuste la posición según describe el paso Procedimiento aProcedimiento C Igual a 18, salte al paso 7. Si no, corte lasDel soporte de pared Drenaje de la unidad, retire el envoltorio de lasEl ajuste se muestra en pantalla Instruccionnes de FuncionamientoControles Del ventilador, control de temperatura en 72 FIncrementos de 1 F Control remotoReinicio automático El ajuste aparece en pantallaDirección del aire Cómo Poner Las BateriasVentilación Como agregar la rejilla frontal al gabinete Cuidado y MantenimientoLimpieza del filtro de aire Operación anormal Problemas y soluciones habitualesOperación normal Gire el control de Temperatura a un número más bajoNota Nota Aire Acondicionador Garantía Limitada DEL Aire Acondicionador LG EE.UU LG Room AIR Conditioner Limited Warranty USA Patent No. Us 6, 412 No A21004Q