LG Electronics LT1030CR owner manual Operating Instructions, Controls

Page 18

Operating Instructions

Operating Instructions

Controls

The controls will look like one of the following.

FAN SPEED

Every time you push this button, it advances the setting as follows: {High Low Med High}

Cool

F1 LOW

'F

Energy

F2 MED

 

F3 HIGH

 

Saver

 

 

Fan

Timer TEMP

FAN

MODE TIMER SPEED POWER

TIMER

-SHUT-OFF TIME

You will usually use shut-off time while you sleep.

If unit is running, use Timer to set number of hours until shut-off.

For your sleeping comfort, once Time is set, the Temperature setting will raise 2°F after 30 min., and once again after another 30 min.

Push Timer button to advance setting from 1Hour 2Hours ...

12Hours maximum.

-START TIME

If unit is off, use Timer to set number of hours before unit starts.

Push Timer button to advance setting from 1Hour 2Hours ...

12Hours maximum.

REMOTE CONTROL SIGNAL RECEIVER

TEMPERATURE SETTING

Use this button to automatically control the temperature of the room.

The temperature can be set within a range of 60°F to 86°F by increments of 1°F.

The setting appears in the display.

POWER

To turn the air conditioner ON, push this button. To turn the air conditioner OFF, push the button again.

This button takes priority over any other button.

When you first turn it on, the unit is in cool

mode, High fan speed, Temperature setting at 72°F.

MODE

-Push this button to shift mode of operation from COOL ENERGY SAVER FAN.

-COOL:

Fan runs continually for normal cooling operation.

-ENERGY SAVER:

The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed.

-FAN:

Fan-only operation.

AUTO RESTART

When power is restored after an electrical power failure, the unit will begin to run at its last setting.

18Room Air Conditioner

Image 18
Contents Room AIR Conditioner Table of Contents Outlet Power cord length Is damaged Safety PrecautionsDon’t use a power cord, a Always plug into a grounded Be caution when unpacking and installingCome from it During operation Unplug the unit if strangeSounds, odors, or smoke Ventilate the room well whenOtherwise, it may cause vibration or water leakage Hold the plug by the head When gas leaks, openKeep level parallel in installing the product It will cause electric shock or fireDo not step on Always insert the filter Sharp edges when Perform ventilation Installing SometimesDo not block the inlet or outlet of air flow Be cautious not to touchBefore Operation Cleaning and MaintenanceService Preparing for OperationSymbols Used in this Manual FeaturesIntroduction Electrical Data Electrical SafetyUse Wall Receptacle Power Supply Wash hands after handlingElectrical Safety Please Read CarefullyInstallation Installation RequirementsInstallation HOW to InstallSupplied with your unit,skip to step Procedure aInstall the new unit into the wall sleeve To the wall sleeve. If you need plastic nuts toProcedure B Top ViewFasten the screws Procedure a WallProcedure C Remove the backing from the HorizontalRemove the backing from the support blocks To achieve rearward slope for unit draining Remove the backing from the 1113/16 shimOperating Instructions ControlsRemote control Increments of 1 FFAN Fan-only operation How to insert Batteries VentilationAir Direction Maintenance and Service Air Filter CleaningHow to Attach Front Grille to Cabinet Common Problems and Solutions TroubleshootingNormal Operation Memo Escriba aquí el modelo y número de serie Modelo n Serie nNombre del distribuidor Fecha de compra No desmonte ni modifique Tenga cuidado al Los productos Precauciones de SeguridadToma a tierra AparatoNo ponga el cable de alimentación cerca de un calentador No dañe ni use un enchufe de alimentación no especificado Sostenga el enchufe por su cabeza al sacarloMantenga nivelado el producto al instalarlo No se suba a la unidad Inserte siempre el filtro Puntiagudos al instalar Ocasiones Del aire durante elLimpieza y mantenimiento Preparación para el funcionamientoUso ServicioIntroducción Símbolos Utilizados en Este ManualCaracterísticas Seguraida Electrica Datos ElectricosSeguraida Electrica Importante Favorlea CON AtenciónPeríodo de tiempo InstalacionRequisitos DE Instalación Frontal y posteriorInstalación Cómo InstalarProcedimiento a ParedColoque la rejilla plástica Procedimiento BPerspectiva superior Apriete los tornillosAjuste la posición según describe el paso Procedimiento aProcedimiento C Igual a 18, salte al paso 7. Si no, corte lasDel soporte de pared Drenaje de la unidad, retire el envoltorio de lasEl ajuste se muestra en pantalla Instruccionnes de FuncionamientoControles Del ventilador, control de temperatura en 72 FIncrementos de 1 F Control remotoReinicio automático El ajuste aparece en pantallaCómo Poner Las Baterias VentilaciónDirección del aire Cuidado y Mantenimiento Limpieza del filtro de aireComo agregar la rejilla frontal al gabinete Operación anormal Problemas y soluciones habitualesOperación normal Gire el control de Temperatura a un número más bajoNota Nota Aire Acondicionador Garantía Limitada DEL Aire Acondicionador LG EE.UU LG Room AIR Conditioner Limited Warranty USA Patent No. Us 6, 412 No A21004Q