LG Electronics 3828A20025U manual Preparation of Piping

Page 13

Installation of Unit

PreparationofPiping

Main cause of gas leakage is defect in flaring work. Carry out correct flaring work in the following procedure.

1.Cut the pipes and the cable.

Use the accessory piping kit or the pipes purchased locally.

Measure the distance between the indoor and the outdoor unit.

Cut the pipes a little longer than measured distance.

Cut the cable 1.5m longer than the pipe length.

2.Burrs removal

Completely remove all burrs from the cut cross section of pipe/tube.

Put the end of the copper tube/pipe to downward direction as you remove burrs in order to avoid to let burrs drop in the tubing.

3.Putting nut on

Remove flare nuts attached to indoor and outdoor units, than put them on pipe/tube having completed burr removal.

(Not possible to put them on after flaring work)

4.Flaring work

Carry out flaring work using dedicated flaring tool as shown below.

Outside diameter

A

mm

inch

mm

Ø6.35

1/4

1.1~1.3

Ø9.52

3/8

1.5~1.7

Ø12.7

1/2

1.6~1.8

Ø15.88

5/8

1.6~1.8

Ø19.05

3/4

1.9~2.1

Firmly hold copper tube in a bar(or die) as indicated dimension in the table above.

5.Check

Compare the flared work with figure below.

If flare is noted to be defective, cut off the flared section and do flaring work again.

Copper

 

Slanted

Uneven Rough

tube

90°

 

 

Pipe

 

 

 

Reamer

Point down

Flare nut

Copper tube

 

Handle

Bar

Bar

"A"

Yoke

 

Cone

Copper pipe

Clamp handle

Red arrow mark

Smooth all round

 

 

Inside is shining without scratches

 

= Improper flaring =

Inclined

Surface

Cracked Uneven

Even length

damaged

thickness

 

 

all round

 

 

12Floor Standing type Air Conditioner

Image 13
Contents No A20025U LG Floor Standing Type Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction InstallationAlways ground the product Use the correctly rated breaker or fuseOperation Be sure the installation area does not deteriorate with ageKeep level even when installing the product Installation or repair of product Drained away properlyUse two or more people to lift and transport the product Indoor unit Selection of the best locationOutdoor unit Piping length and the elevation Outdoor unit Installation Indoor Unit InstallationRefrigerant amount Selecting the locationOutdoor Unit Installation guide at the seasideInstallation works Descriptions Installation MethodInstallation Parts, Tools Use Preparation of installation parts and toolsPreparation of Piping Connection of piping Precautions in bendingMove the indoor tubing and drain hose to the hole Wiring DetailsB Connecting the Cable to Indoor UnitConnecting the cables to the outdoor unit Connecting pipings to the outdoor unitConnect wires to the terminals on the control Power supply Power Supply and WiringWiring Vacuum Drying of the Connecting Pipes and the Indoor Unit Form the Piping Final Check and Test Run