LG Electronics 3828A20025U manual Selection of the best location, Indoor unit, Outdoor unit

Page 7

Installation of Unit

Installation of Unit

Selectionofthebestlocation

1.Indoor unit

There should not be any heat source or steam near the unit.

There should not be any obstacles to prevent the air circulation.

A place where air circulation in the room will be good.

A place where drainage can be easily obtained.

A place where noise prevention is taken into consideration.

Do not install the unit near the door way.

Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.

The indoor unit must keep the maintenance space.

40cm 100cm

5cm 40cm

2.Outdoor unit

If an awning is built over the unit to prevent direct sunlight or rain exposure, be careful that heat radiation from the condenser is not restricted.

There should not be any animals or plants which could be affected by hot air discharged.

Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.

 

 

Sunroof

More than

 

 

50cm

 

 

 

 

More than

 

 

350cm

Fence

or

More

than 50cm

obstacles

More than 100cm

 

 

6Floor Standing type Air Conditioner

Image 7
Contents No A20025U LG Floor Standing Type Air Conditioner Table of Contents Use the correctly rated breaker or fuse InstallationBe sure not to do Be sure to follow the instruction Always ground the productOperation Be sure the installation area does not deteriorate with ageKeep level even when installing the product Installation or repair of product Drained away properlyUse two or more people to lift and transport the product Indoor unit Selection of the best locationOutdoor unit Piping length and the elevation Outdoor unit Installation Indoor Unit InstallationRefrigerant amount Selecting the locationOutdoor Unit Installation guide at the seasideInstallation works Descriptions Installation MethodInstallation Parts, Tools Use Preparation of installation parts and toolsPreparation of Piping Connection of piping Precautions in bendingMove the indoor tubing and drain hose to the hole Wiring DetailsB Connecting the Cable to Indoor UnitConnecting the cables to the outdoor unit Connecting pipings to the outdoor unitConnect wires to the terminals on the control Power supply Power Supply and WiringWiring Vacuum Drying of the Connecting Pipes and the Indoor Unit Form the Piping Final Check and Test Run