Henny Penny EEG-144, EEG-142, EEG-141, EEG-143 warranty Error Codes, Display, Cause, Correction

Models: EEG-143 EEG-144 EEG-141 EEG-142

1 72
Download 72 pages 1.4 Kb
Page 70
Image 70
Manual background

Model EEG-141, 142, 143, 144

7-2. ERROR CODES

 

 

 

DISPLAY

CAUSE

CORRECTION

 

 

 

“E-20-A”

• Pressure Switch

• If fan is not running, have pressure switch checked; should be

“FAN SENSOR

failure

open circuit if no air pressure

STUCK

• wiring problem

• If fan is running, wiring error, or relay on I/O board closed

CLOSED”

• I/O board failure

 

 

 

 

“E-20-B”

• Pressure Switch

• Press power button to vat off and back on again, if E-20-B

“NO DRAFT”

failure/hose loose

persists, have pressure switch checked; should be open circuit

“CHECK

• Draft Fan failure/

if no air pressure; make sure hose is connected to fan and

FAN”

low voltage

pressure switch

 

• Flue or hood

• Have draft fan checked; low voltage going to fan

 

obstructions

• check the fryer flue and hood system for obstructions

 

 

 

“E-20-D”

• Failure to ignite/

• Press power button to vat off and back on again, if E-20-D

“IGNITION”

no flame sense

persists, check gas line connections; check gas shut-off valve;

“FAILURE”

 

have ignition module checked; gas valve checked; flame sensor

 

 

gap checked; gas valve and ignition module wiring checked

 

 

 

“E-21”

• Slow heat recovery

• Have a certified service technician check the fryer for correct

 

 

voltage to the unit; have heat circuit checked; have unit

 

 

checked for loose or burnt wire

 

 

 

“E-22”‘NO

• Burner not igniting

• Have gas valve and heat circuit checked

HEAT” “CHECK

 

 

GAS VALVE”

 

 

 

 

 

“E-41”, “E-46”

• Programming

• Press power button to vat off and back on again, if any

 

failure

of the error codes, have the controls re-initialized; if error code

 

 

persists, have the control board replaced

 

 

 

“E-47”

•Analog converter

• Press power button to vat off and back on again, if “E-47”

 

chip or 12 volt

persists, have the I/O board, or the PC board replaced; if

 

supply failure

speaker tones are quiet, probably I/O board failure; have the

 

 

I/O boardreplaced

 

 

 

“E-48”

• Input system error

• Have PC board replaced

 

 

 

“E-54C”

• Temperature input

• Turn switch to OFF, then back to ON; have control PC board

 

error

replaced if “E-54C” persists

 

 

 

“E-60”

• AIF PC board not

• Press power button to vat off and back on again if “E-60”

 

communicating with

persists, have the connector between the PC boards checked;

 

control PC board

replace AIF PC board or control PC board if necessary

7-4

 

809

Page 70
Image 70
Henny Penny EEG-144, EEG-142, EEG-141, EEG-143 warranty Error Codes, Display, Cause, Correction