3-10. MODEL EEG-141 OIL

RESERVOIR

Figure 1

Figure 2

Figure 3

Figure 4

510

Model EEG-141, 142, 143, 144

Filling Oil Reservoir

1.Control displays “JIB IS LOW” and an alarm sounds.

2.Open door and pull reservoir forward and remove reservoir cover. Figure 1.

3.Place on bracket on door. Figure 2.

4.Pour oil into reservoir upto the fill lines (13 lbs. (6.12 kg.)) and then replace cover and push reservoir back into position. Figure 3.

Removing/Cleaning Reservoir

1.Open door and pull reservoir forward.

2.Slide reservoir to the left and lift from fryer. Figure 4.

3.Clean reservoir at a sink with soap and water.

Before placing the reservoir back into position, lubricate the o-rings (below) on the filter tube with cold oil. Check o-rings for tears or nicks and replace if necessary.

To replace o-ring, use a small, flat-bladed screwdriver, pry up on the o-ring and pull off of end of tube. See below.