3-22. CLEAN BLOWER & VENTS

3-22. CLEAN BLOWER & VENTS

Figure 1

Figure 2

Figure 3

Figure 4

1109

Model EEG-141, 142, 143, 144

To ensure proper burner operation, clean the blowers and blower vents twice a year.

1.Press the main power switch to the OFF posistion.

2.Unplug power cord and turn the gas shut-off handle clockwise to turn off the gas, and then disconnect the gas line.

3.Disconnect cable restraint and then carefully roll the fryer from the hood far enough to get behind the fryer.

To avoid burns, use care when moving the fryer to prevent hot cooking oil from splashing.

4.Using a cloth or paper towel, clean the blower intake slots to ensure sufficient air flow to the blowers. Figure 1.

5.Using a Phillip’s-Head screwdriver, remove lower, rear panel. Figure 2.

6.Using a cloth or paper towel, clean each blower opening. Figure 3.

7.Clean the vent slots on the inside of rear panel, and then replace panel. Figure 4.

8.Reattach the gas line and turn the shut-off handle counter- clockwise to turn on the gas and reconnect the cable restraint to the fryer.

9.Reattach the plug to electrical receptacle and roll fryer back into place.