2-7. GAS LEAK TEST

2-7. GAS LEAK TEST

2-8. GAS PRESSURE REGULATOR SETTING

2-9. ELECTRICAL REQUIREMENTS

Model EEG-141, 142, 143, 144

Prior to turning the gas supply on, be sure the gas valve knob on the gas control valve is in the off position.

Upon initial installation, and after moving the unit, the piping and fittings should be checked for gas leaks.Asimple checking method is to turn on the gas and brush all connections with a soap solution. If bubbles occur, it indicates escaping gas. In this event, the piping connection must be redone.

To avoid fire or explosion, never use a lighted match or open flame to test for gas leaks. Ignited gas could result in severe personal injury and/or property dam- age.

The gas pressure regulator on the gas control valve is factory set as follows:

Natural: 3.5 inches water column (0.87 kPa) (8.72 mbar).

Propane 10.0 inches water column (2.49 kPa) (24.9 mbar).

The gas pressure regulator has been set by Henny Penny and is not to be adjusted by the user.

120 V, 50/60 Hz, 1 PH, 12 A

230 V, 50 Hz, 1 PH, 7 A

The 120 volt gas fryer is factory equipped with a grounded (earthed) cord and plug for your protection against shock, and should be plugged into a three-prong grounded (earthed) recep- tacle. Do not cut or remove grounding (earthing) prong. Any 230 volt plug used on the 230 volt unit must conform to all local, state, and national codes.

To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors. The main power switch on this appliance does not disconnect all line conductors.