5-1. MODIFYING PRODUCT SETTINGS (Continued)

5-3

Model EEG-141, 142, 143, 144

MixFilterdAfterFil TrackingX Number of Loads

13b. Press >Load Compensation, Load Compensation Reference, Full Heat, PC Factor< button until “FILTER AFTER...” flashes in the left display along, and the number of cook cycles between filters shows in the right display. Press the product buttons, or the Manual background and Manual backgroundbuttons, to change this value of 0 to 99 loads. This needs set for each product.

>Load Compensation, Load Compensation Reference, Full Heat, PC Factor<

14.Press Manual background button until “LD COMP” shows in the display, along with the load compensation value. This automatically adjusts the time to account for the size and temperature of the cooking load.

Press the product buttons, or theManual background and Manual background buttons, to change this value of 0 to 20.

15.Press Manual background button until “LCMP REF” shows in the display along with the load compensation average temperature. (if load compensation is set to “OFF”, then “_ _ _” shows in display and setting cannot be programmed) This is the average

cooking temperature for each product. The timer speeds up at temperatures above this setting and slows down at temperatures below this setting. Press the product button, or the and buttons, to change this value.

16. Press button until “FULL HT” shows in the display along with the full heat value in seconds, which means the heat is on as soon as a timer button is pressed, for the programmed length of time. Press the product buttons, or theManual background and Manual background buttons, to change this value of 0 to 90 seconds.

17. Press button until “PC FACTR” shows in the display along with the proportional temperature, which helps to keep the oil from over-shooting the setpoint temperature. Press the product buttons, or the Manual background and Manual background buttons, to change this value of 0 to 50 degrees.

Use

button to go back to previous menu items.

Press

button when finished with the current product, to

 

return to the “SELECT PRODUCT” step.

Press and hold

button to exit PRODUCT PROGRAM

 

Mode.

 

 

 

 

 