Model EEG-141, 142, 143, 144

3-18. CHECK/REPLACE FILTER DRAIN PAN O-RINGS

To prevent oil leaking, and to keep filtering process operating properly, the filter drain pan o-rings should be inspected for nicks and tears at least every 3 months. Figure 1

Figure 1

1.Open the door, lift-up on the drain pan stop and pull-out the filter drain pan assembly, using the handle on the drain pan. Figures 2 & 3

Figure 2

This pan could be hot! Use protective cloth or glove, or severe burns could result.

2.Visually check the 3 o-rings on the tube of the filter drain pan for any cracks or breaks and replace if necessary.

Figure 3

3.To replace o-ring, use a small, flat-bladed screwdriver, pry up on the o-ring and pull off of end of tube. Roll new o-ring into notch on tube. Before pushing the filter drain pan back into position, lubricate the o-rings on the filter tube with fresh, cold oil.

Figure 4

3-23

609

Page 44
Image 44
Henny Penny EEG-142, EEG-141, EEG-144, EEG-143 warranty CHECK/REPLACE Filter Drain PAN O-RINGS