6-1. SPECIAL PROGRAM MODE (Continued)

6-8

Model EEG-141, 142, 143, 144

Autolift Enabled (SP-21)

Press button and “SP-21 AUTOLIFT ENABLED?” flashes in the left display. Press the or buttons to choose “YES LIFT” or “NO LIFT”.

If fryer is fitted with the auto-lift option, SP-21 must be set to “YES LIFT”, otherwise, set SP-21 to “NO LIFT”.

Bulk Oil Supply (SP-22)

Press button and “SP-22 BULK OIL SUPPLY?” flashes in the left display. Press the or buttons to choose “YES SUPL” or “NO SUPL”.

Set to YES if the oil is pumped into the vats from an outside oil reservoir. Otherwise, set SP-22 to NO.

Bulk Oil Disposal (SP-23)

Press button and “SP-23 BULK OIL DISPOSE?”

flashes in the left display. Press the or buttons to choose “YES DISP” or “NO DISP”.

Set to “YES DISP” if the oil is pumped from the vats to an outside oil reservoir when disarding the oil. Otherwise, set SP-23 to “NO DISP”.

Serial Number Log (SP-24)

Press button and “SP-24 S/N √EDIT” flashes in the displays, along with the serial number of the unit. THIS SERIAL NUMBER SHOULD MATCH THE SERIAL NUMBER ON THE DATA PLATE, ON THE DOORS. IF NOT, IT CAN BE RECORDED.

Program Code Change (SP-25)

This allows the operator to change the program code (factory set at 1, 2, 3) used to access Product Programming and Level 2 Program Mode.

Press button and “SP-25 CHANGE MGR CODE? 1=YES” flash in the display. Press and “ENTER NEW CODE, P=DONE, I=QUIT show scrolls through the display. Press the product buttons for new code.

If satisfied with code, press and “REPEAT NEW CODE, P=DONE, I=QUIT, shows in display. Press same code buttons.