Henny Penny EEG-142 Filter Tracking Mode SP-8, Mixed, SPECIAL PROGRAM MODE Continued, Cycle, Fish

Models: EEG-143 EEG-144 EEG-141 EEG-142

1 72
Download 72 pages 1.4 Kb
Page 60
Image 60
Cycle

6-1. SPECIAL PROGRAM MODE (Continued)

 

No. Cook

Cycle

Product

Cycles

Count

Fish

2

1/2

French Fries

8

1/8

Chicken

4

1/4

Model EEG-141, 142, 143, 144

Filter Tracking Mode (SP-8)

Filter Tracking signals the operator when the oil needs filtering by counting the number Cook Cycles between filters

Press Product button and “SP-8” and “FILTER TRACKING MODE” show in the display. Use the Cycles and Count buttons to choose either “1.MIXED” filter tracking or “2.GLOBAL”.

GLOBAL means all the products have the same number of cook cycles between filters.

MIXED means each product may be set with different number of cook cycles between filters. The controls adds the

cycle counts (see example at left) and when the counts equal 1 or greater, filtering is suggested. Ex: 1 load of fish, 2 loads of french fries, a load of chicken equals 1. 1/2 + 1/8+1/8+1/4=1.

MIXED

If MIXED is selected, press Fish button and “SP-8A” and “SUGGEST FILTERAT …” shows in the left display, and a value between 75% and 100% shows on the right display. Press the French Fries and Chickenbuttons to change this value.

The lower the value, the sooner the control recommends to filter. Ex: If set to 75%, the control suggest filtering after 3/4 of the programmed cook cycles is met, whereas at 100%, all the cook cycles must be completed before the control suggest filtering.

Press Filter Tracking Mode (SP-8) and “SP-8B” and “LOCKOUT ENABLED?” shows in the left display. Press the MIXED and Manual background buttons to choose YES or NO.

If set toYES, when the controls suggest filtering, “FILTER LOCKOUT”/”YOU *MUST* FILTER NOW”, shows in the display, and it refuses further cook cycles until the vat is filtered.

Press Manual background and “SP-8C” and “LOCKOUT AT...” shows in the left display and a value between 100% and 250% shows on the

right display. Press the Manual background and Manual background buttons to change this value. The lower the value, the sooner the “lockout” occurs.

Ex: If set at 100%, “lockout” occurs when the cycle counts reaches 1 or greater. Set at 200%, twice as many cycles are counted before “lockout” occurs. See example above.

6-4

909