Henny Penny EEG-141, EEG-142, EEG-144, EEG-143 warranty SMARTFILTER EXPRESS Continued, Filter Error

Models: EEG-143 EEG-144 EEG-141 EEG-142

1 72
Download 72 pages 1.4 Kb
Page 33
Image 33
3-11. SMARTFILTER EXPRESS™ (Continued)

3-11. SMARTFILTER EXPRESS™ (Continued)

Model EEG-141, 142, 143, 144

6. If the oil has not pumped back to the proper levelXin the vat during the SmartFilter Express™ process, press button for NO and pump runs for another 30 seconds.

7.Display shows “IS POT FILLED?” “YES NO”. Make sure

vat is full and then press √ button and displayX shows and the control returns to normal operation. Press button and pump

runs for another 30 seconds. You can try to fill the vat 3 times.

Filter Error

8.After trying to fill the vat 3 times without success, the controls

then shows “CHANGE FILTER PAD?” “YES NO”. If changing the filter pad at this time, press √ and change filter pad following the procedures in the Changing the Filter Pad Section. Controls return to normal operation.

If filter pad is to be changed at a later time, press X button and “CHANGE FILTER PAD?” reminder shows 15 minutes later.

9.During the next SmartFilter Express™ with a new filter pad, if the vat is not filled after 3 tries, the display shows “FILTER SERVICE REQUIRED-SEE TROUBLESHOOTING GUIDE”.

If the “Service Required” message appears, then every 15 minutes the display shows “FILTER PROBLEMX FIXED? YES NO”. If the problem has not been fixed, press button. Once the problem has been resolved, press √ and controls return to normal operation.

To help ensure the vat fills completely, make sure filter pan is cleaned at least daily, filter pad is changed, make sure JIB is full and that “O” rings on the filter pan are in good condition.

609

3-12

Page 33
Image 33
Henny Penny EEG-141, EEG-142, EEG-144, EEG-143 warranty SMARTFILTER EXPRESS Continued, Filter Error