2-9. ELECTRICAL REQUIREMENTS (Continued)
2-10. MOTOR BEARINGS
2-11. LIGHTINGAND SHUTDOWN OF THE BURNERS
609
Model EEG-141, 142, 143, 144
To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded (earthed). Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No.
Disconnect power supply before a thorough cleaning or servicing the fryer
The electric motor bearings are permanently lubricated. DO NOT LUBRICATE.
1.Turn the power switch to the OFF position.
2.Wait at least 5 minutes and then turn the power switch to the ON position.
3.Press button on the controls (left or right).
4.The burner lights and operates in a Melt Cycle until the shortening reaches a preset temperature.
6.Once the display shows a product selection or a double dashes, press the desired product button.
The fryer is equipped with a ignition spark module which has a set ignition safety time (TSA) of 90 seconds.
To shutdown burner:
1. Press | button on the controls (left or right). |
2.Turn the power switch to the OFF position. NOTE: This turns off all vats.