Henny Penny EEG-143, EEG-142, EEG-141 ELECTRICAL REQUIREMENTS Continued 2-10. MOTOR BEARINGS

Models: EEG-143 EEG-144 EEG-141 EEG-142

1 72
Download 72 pages 1.4 Kb
Page 19
Image 19
2-9. ELECTRICAL REQUIREMENTS (Continued)

2-9. ELECTRICAL REQUIREMENTS (Continued)

2-10. MOTOR BEARINGS

2-11. LIGHTINGAND SHUTDOWN OF THE BURNERS

609

Model EEG-141, 142, 143, 144

To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded (earthed). Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No.

70-(the current edition). In Canada, all electrical connections are to be made in accordance with CSA C22.2, Canadian Electrical Code Part 1, and/or local codes.

Disconnect power supply before a thorough cleaning or servicing the fryer

The electric motor bearings are permanently lubricated. DO NOT LUBRICATE.

1.Turn the power switch to the OFF position.

2.Wait at least 5 minutes and then turn the power switch to the ON position.

3.Press 2-11. LIGHTINGAND SHUTDOWN OF THE BURNERS button on the controls (left or right).

4.The burner lights and operates in a Melt Cycle until the shortening reaches a preset temperature.

6.Once the display shows a product selection or a double dashes, press the desired product button.

The fryer is equipped with a ignition spark module which has a set ignition safety time (TSA) of 90 seconds.

To shutdown burner:

1. Press

button on the controls (left or right).

2.Turn the power switch to the OFF position. NOTE: This turns off all vats.

2-7

Page 19
Image 19
Henny Penny EEG-143, EEG-142 ELECTRICAL REQUIREMENTS Continued 2-10. MOTOR BEARINGS, Lightingand Shutdown Of The Burners