3. INSTALLATION

3.1 HOW TO INSTALL THE UNIT

CAUTION

There are sharp edges that can cause serious cuts.

When lifting the air conditioner, it is HEAVY. Use 2 peoples to lift.

For existing sleeve, you should measure the wall sleeve dimensions.

You can install the new air conditioner according to these installation instructions to achieve the best performence. All wall sleeves used to mount the new air conditioner must be in good structural condition and have the rear grille that securely attaches to the sleeve or the flange of the sleeve to secure the new air conditioner.

To avoid vibration and noise, make sure the unit is installed securely and firmly.

Dimension of air conditioner

1,066mm(42")

406mm (16")

318mm (12 1/2")

505mm

(20")

Dimension of sleeve assembly (optional)

1066mm

(42")

406mm

(16")

318mm (12 1/2")

A. BEFORE ATTACHING THE FRONT GRILLE TO THE SLEEVE, IF YOU WANT TO PULL OUT THE FILTER UPWARD;

1.There should be no obstacle, like a fence, within 20" which might restrict heat radiation from the condenser.

B. IF YOU WANT TO PULL OUT THE FILTER DOWNWARD;

The grille is already designed for that way.

1.Install the unit a little obliquely outward not to leak the condensed water into the room (about 1/2" or 1/4" bubble with level).

2.Install the unit with its bottom portion 30~60" above the floor level.

3.The power cord must be connected to an independent circuit. The green wire must be grounded.

INSULATION

COOLED

AIR

INTAKE

AIR

1/4" Bubble of the level

WALL

SLEEVE

 

 

 

HEAT

RADIATION

WALL

Over 20"

 

1/4" Bubble

Level

—17—

Image 17
Contents LG Room Air Conditioner Preface ContentsCooling / Heat Pump / Electric SpecificationsCooling / Electric Heater Features Condensate Drain Valve Operation Electric Heating Model Control LocationsVentilation Cooling only ModelAdditional Controls Temperature LimitingRemoving the Front Grille Additional ControlsEnergy Saver REMOTE/LOCAL ControlFront Desk Control Remote Wall ThermostatFront Grille Disassembly InstructionsMechanical Parts Control BOX Full-Disassembly Control BOX Half-Disassembly2 FAN Heater Assembly and Cross Flow FANAIR Handling Parts Shroud Electrical PartsOutdoor Motor Compressor6 P.C.B Power CordCondenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Dimension of air conditioner HOW to Install the UnitDimension of sleeve assembly optional If YOU Want to Pull OUT the Filter DownwardPreparation of the Front Grille Suggested Tool RequirementsSleeve Hardware Assemble the Wall SleeveUnit Installation Electrical Requirements Electrical SafetyElectrical Data for 230/208V Model Important Grounding InstructionsHeat Pump Performance Data Air Conditioner Performance DataLP120CEM Cooling Wattage Air ConditionersCooling Wattage Heat Pumps Cooling Change of Temperature Heat Pumps Cooling change of temperature Air ConditionersCooling Ampere Chart Heat Pumps Heating Change of Temperature Heat PumpsCooling Ampere Chart Air Conditioners Piping System Troubleshooting GuideOutside Dimensions Troubleshooting Guide Fails to Start Complaint Cause Remedy Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Location Description QTY Remarks PER SET Schematic DiagramExploded View Description Remark LP090HEM LP120CEM LP120HEM Replacement Parts ListNo A20308H May