LG Electronics 230/208V service manual Cooling Wattage Heat Pumps

Page 23

Cooling Wattage - Heat Pumps

Model

 

LP090HM*

LP120HEM

 

Temperature

 

 

 

 

Outdoor

Return Air

Total Wattage

Total Wattage

Air

Dry Bulb

Wet Bulb

 

Input

Input

 

 

 

Min

Max

Min

Max

Rating Wattage

810

850

1120

1145

 

 

 

 

 

 

 

85

830

935

1120

1230

 

80

835

940

1125

1235

 

75

835

940

1130

1240

100

70

835

940

1125

1240

 

65

830

935

1120

1230

 

60

820

925

1115

1230

 

55

810

915

1100

1210

 

85

785

890

1070

1180

 

80

790

890

1075

1190

 

75

795

890

1075

1190

95

70

790

890

1075

1190

 

65

785

890

1070

1180

 

60

780

880

1060

1170

 

55

770

865

1050

1160

 

85

745

845

1020

1130

 

80

750

850

1025

1135

 

75

750

850

1025

1135

90

70

750

850

1025

1125

 

65

745

845

1020

1130

 

60

735

835

1010

1120

 

55

720

825

1000

1110

 

85

700

800

970

1080

 

80

705

800

975

1085

 

75

705

810

975

1085

85

70

705

800

975

1085

 

65

700

800

970

1080

 

60

690

790

960

1070

 

55

680

775

950

1060

 

85

655

755

920

1030

 

80

660

760

925

1030

 

75

660

760

925

1035

80

70

660

760

920

1030

 

65

655

755

920

1030

 

60

650

745

910

1020

 

55

635

735

900

1010

—23—

Image 23
Contents LG Room Air Conditioner Preface ContentsCooling / Heat Pump / Electric SpecificationsCooling / Electric Heater Features Condensate Drain Valve Cooling only Model Control LocationsOperation Electric Heating Model VentilationAdditional Controls Temperature LimitingAdditional Controls Removing the Front GrilleRemote Wall Thermostat REMOTE/LOCAL ControlEnergy Saver Front Desk ControlFront Grille Disassembly InstructionsMechanical Parts Control BOX Full-Disassembly Control BOX Half-Disassembly2 FAN Heater Assembly and Cross Flow FANAIR Handling Parts Compressor Electrical PartsShroud Outdoor Motor6 P.C.B Power CordCapillary Tube Refrigeration CycleCondenser EvaporatorPage Pulling Vacuum If YOU Want to Pull OUT the Filter Downward HOW to Install the UnitDimension of air conditioner Dimension of sleeve assembly optionalAssemble the Wall Sleeve Suggested Tool RequirementsPreparation of the Front Grille Sleeve HardwareUnit Installation Important Grounding Instructions Electrical SafetyElectrical Requirements Electrical Data for 230/208V ModelHeat Pump Performance Data Air Conditioner Performance DataLP120CEM Cooling Wattage Air ConditionersCooling Wattage Heat Pumps Cooling Change of Temperature Heat Pumps Cooling change of temperature Air ConditionersCooling Ampere Chart Heat Pumps Heating Change of Temperature Heat PumpsCooling Ampere Chart Air Conditioners Piping System Troubleshooting GuideOutside Dimensions Troubleshooting Guide Fails to Start Complaint Cause Remedy Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Location Description QTY Remarks PER SET Schematic DiagramExploded View Description Remark LP090HEM LP120CEM LP120HEM Replacement Parts ListNo A20308H May