LG Electronics 230/208V Air Conditioner Performance Data, Heat Pump Performance Data

Page 21

4. PERFORMANCE DATA

Air Conditioner Performance Data

LP120CEM

Voltage (V)

208 230

208 230

Cooling Data

 

 

Cooling Capacity

 

 

(Btu/h)

11,500

11,800

Cooling Amps (A)

4.8

5.2

Cooling Power (W)

1025

1055

EER (Btuh/Watt)

11.0

11.0

Moisture Removal

 

 

(Pts/h)

3.3

3.3

Airflow

 

 

Indoor CFM (Wet)

 

 

@0.3ESP (Hi)

300

330

Indoor CFM (Wet)

 

 

@0.3ESP (Lo)

290

290

Indoor CFM (Dry)

 

 

@0.3ESP (Hi)

320

350

Indoor CFM (Dry)

 

 

@0.3ESP (Lo)

280

310

Heat Pump Performance Data

 

LP120HEM

 

LP090HEM

Voltage (V)

208 230

208 230

208

230

Cooling Data

 

 

 

 

Cooling Capacity (Btu/h)

11,800

12,100

9,000

9,300

Cooling Amps (A)

5.4

5.0

3.9

3.7

Cooling Power (W)

1,065

1,090

775

800

EER (Btuh/Watt)

11.1

11.1

11.6

11.6

Moisture Removal (Pts/h)

3.3

3.3

3.4

3.4

Heat Pump Heating Data

 

 

 

 

Heating Capacity (Btu/h)

10,700

10,900

8,000

8,200

Heating Amps (A)

4.8

4.4

3.5

3.2

Heating Power (W)

950

970

690

705

COP (W/W)

3.3

3.3

3.4

3.4

Airflow

 

 

 

 

Indoor CFM (Wet)

240

270

310

340

@0.3ESP (Hi)

Indoor CFM (Wet)

 

 

 

 

@0.3ESP (Lo)

190

230

270

300

Indoor CFM (Dry)

 

 

 

 

@0.3ESP (Hi)

260

290

330

360

Indoor CFM (Dry)

 

 

 

 

@0.3ESP (Lo)

220

250

290

330

—21—

Image 21
Contents LG Room Air Conditioner Preface ContentsSpecifications Cooling / Electric HeaterCooling / Heat Pump / Electric Features Condensate Drain Valve Operation Electric Heating Model Control LocationsVentilation Cooling only ModelAdditional Controls Temperature LimitingRemoving the Front Grille Additional ControlsEnergy Saver REMOTE/LOCAL ControlFront Desk Control Remote Wall ThermostatDisassembly Instructions Mechanical PartsFront Grille Control BOX Full-Disassembly Control BOX Half-DisassemblyHeater Assembly and Cross Flow FAN AIR Handling Parts2 FAN Shroud Electrical PartsOutdoor Motor Compressor6 P.C.B Power CordCondenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Dimension of air conditioner HOW to Install the UnitDimension of sleeve assembly optional If YOU Want to Pull OUT the Filter DownwardPreparation of the Front Grille Suggested Tool RequirementsSleeve Hardware Assemble the Wall SleeveUnit Installation Electrical Requirements Electrical SafetyElectrical Data for 230/208V Model Important Grounding InstructionsHeat Pump Performance Data Air Conditioner Performance DataLP120CEM Cooling Wattage Air ConditionersCooling Wattage Heat Pumps Cooling Change of Temperature Heat Pumps Cooling change of temperature Air ConditionersHeating Change of Temperature Heat Pumps Cooling Ampere Chart Air ConditionersCooling Ampere Chart Heat Pumps Troubleshooting Guide Outside DimensionsPiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Location Description QTY Remarks PER SET Schematic DiagramExploded View Description Remark LP090HEM LP120CEM LP120HEM Replacement Parts ListNo A20308H May