3.3ELECTRICAL REQUIREMENTS

3.3.1ELECTRICAL DATA (FOR 230/208V MODEL)

CAUTION

1.Do not use an extension cord with this unit.

2.When the unit is in the OFF position, the power supply to the electrical controls.

3.Disconnect the power to the unit before servicing the unit.

4.Remove the power cord from the wall receptacle.

5.Remove or turn off the protective device (fuses or circuit breaker).

Wirings including installation of the receptacle must comply with the NEC and local codes, local regulations.

FUSE- Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

3.3.2 ELECTRICAL SAFETY

IMPORTANT GROUNDING INSTRUCTIONS

Tandem

15 A

Perpendicular

20 A

Large Tandem

30 A

230/208 volt receptacle configuration

Air conditioner has a three-prong grounding plug on its power supply cord, which must be plugged into properly grounded three-prong wall receptacle for your protection against possible shock hazard.

FUSE – Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

208, 230, and 208/230 VOLT UNITS

These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged into a matching properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances.

NOTE: DO NOT USE AN EXTENSION CORD on 208, 230, and 208/230 Volt units.

—20—

Image 20
Contents LG Room Air Conditioner Contents PrefaceCooling / Heat Pump / Electric SpecificationsCooling / Electric Heater Features Condensate Drain Valve Control Locations Operation Electric Heating ModelVentilation Cooling only ModelTemperature Limiting Additional ControlsRemoving the Front Grille Additional ControlsREMOTE/LOCAL Control Energy SaverFront Desk Control Remote Wall ThermostatFront Grille Disassembly InstructionsMechanical Parts Control BOX Half-Disassembly Control BOX Full-Disassembly2 FAN Heater Assembly and Cross Flow FANAIR Handling Parts Electrical Parts ShroudOutdoor Motor CompressorPower Cord 6 P.C.BRefrigeration Cycle CondenserEvaporator Capillary TubePage Pulling Vacuum HOW to Install the Unit Dimension of air conditionerDimension of sleeve assembly optional If YOU Want to Pull OUT the Filter DownwardSuggested Tool Requirements Preparation of the Front GrilleSleeve Hardware Assemble the Wall SleeveUnit Installation Electrical Safety Electrical RequirementsElectrical Data for 230/208V Model Important Grounding InstructionsAir Conditioner Performance Data Heat Pump Performance DataCooling Wattage Air Conditioners LP120CEMCooling Wattage Heat Pumps Cooling change of temperature Air Conditioners Cooling Change of Temperature Heat PumpsCooling Ampere Chart Heat Pumps Heating Change of Temperature Heat PumpsCooling Ampere Chart Air Conditioners Piping System Troubleshooting GuideOutside Dimensions Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Name Plate Rating Minimum MaximumComplaint Cause Remedy Schematic Diagram Location Description QTY Remarks PER SETExploded View Replacement Parts List Description Remark LP090HEM LP120CEM LP120HEMNo A20308H May