State Industries GP 6 50YPC T 100, GP 6 40YPC T 100 Limited Residential GAS Warranty, Year

Page 39

LIMITED RESIDENTIAL GAS WARRANTY

THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY in accordance with the warranty terms and conditions specified below.

The warrantor will furnish the ORIGINAL OWNER, 1) a replacement water heater of equivalent size and current model if the glass-lined tank in this water heater leaks and, 2) a replacement part for any component part which fails.

THE WATER HEATER REPLACEMENT MODEL OR PART WILL BE WARRANTED FOR ONLY THE UNEXPIRED PORTION OF THE ORIGINAL WARRANTY. The warranty period will be determined by the original date of purchase of the water heater, or in the absence of a Bill of Sale verifying said date, from the date of manufacture indicated on rating plate affixed to this water heater. This warranty is not transferable and applies to models listed below:

SERIES

TANK

PARTS

6-Year Models

6-Year

6-Year

GP 6

 

 

When the water heater has been used for other than single family residential application;

1.The tank warranty shall be reduced to 1 year for 6 year models and to 3 years for 10 year models.

2.The parts warranty shall be reduced to 1 year for all models.

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is installed and operated in accordance with 1) all local fire codes and plumbing codes, ordinances and regulations,

2)the printed instructions provided with it, 3) good industry practices, and 4) proper safety practices such as but not limited to a properly sized drain pan if installed in an area where leakage from the tank or its connections would result in damage to the area adjacent to the heater. In addition, a new temperature and pressure relief valve, certified by the Canadian Gas Association must have been properly installed and piped to the nearest drain.

This warranty shall apply only when the heater is:

owned by the original purchaser;

installed for indoor operation only;

used at temperatures not exceeding the maximum calibrated setting of its thermostat;

used at water pressure not exceeding the working pressure shown on the heater;

filled with potable water, free to circulate at all times and with the tank free of damaging water sediment or scale deposits;

used in a non-corrosive and non-contaminated atmosphere;

used with factory approved anode(s) installed;

in its original installation location;

in the United States, its territories or possessions, and Canada;

sized in accordance with proper sizing techniques for residential water heaters;

bearing a rating plate which has not been altered, defaced or removed except as required by the warrantor;

used in an open system or in a closed system with a properly sized and installed thermal expansion tank;

operated with properly installed drip leg in the gas supply line;

fired with the fuel for which it was factory built;

fired at the factory rated input;

operated with the inner and outer combustion chamber doors in place and all factory seals to combustion chamber intact.

installed with no attempted, nor actual modification or alteration of the water heater’s design in any way, including but not limited to, the attachment of non- company approved appliances or equipment, including any additional aftermarket equipment introduced into the sealed system.

Any accident to the water heater or any part thereof (including freezing, fire, floods, or lightning), any misuse, abuse or alteration of it, any operation of it in a modified form, any operation of the water heater on desalinated (deionized) water, or any damage caused by attempts to repair tank leaks or parts, will void this warranty. This warranty does not cover water heaters replaced for cosmetic reasons or for reasons of noise, taste, odor, discolored and/or rusty water. This warranty does not apply to water heaters used to heat pools, whirlpools or hot tubs or used for space heating where its sizing does not conform with specifications of the heating component manufacturer.

This warranty gives you specific legal rights, and you may have other rights which vary under the laws of each state. If any provision of this warranty is prohibited or invalid under applicable state law, that provision shall be ineffective to the extent of the prohibition or invalidity without invalidating the remainder of the affected provision or the other provisions of this warranty.

SERVICE AND LABOR RESPONSIBILITY

UNDER THIS LIMITED WARRANTY, THE WARRANTOR WILL PROVIDE ONLY A REPLACEMENT WATER HEATER OR PART THEREOF. THE OWNER IS RESPONSIBLE FOR ALL OTHER COSTS. Such costs may include but are not limited to:

a.Labor charges for service, removal, or reinstallation of the water heater or part thereof.

b.Shipping and delivery charges for forwarding the new water heater or replacement part from the nearest distributor and returning the claimed defective heater or part to such distributor.

c.All cost necessary or incidental for handling and administrative charges, and for any materials and/or permits required for installation of the replacement heater or part.

39

Image 39
Contents Residential GAS Water Heaters Table of Contents Safety Precautions Safe INSTALLATION, USE and ServiceFire or Explosion Hazard GET to Know Your Water Heater GAS Models Typical InstallationConsumer Information Installing Your GAS Water HeaterUnpacking the Water Heater Excessive Weight Hazard Important Information About This Water HeaterLocation Requirements Site LocationCarbon Monoxide Poisoning Hazard State of California Clearances and AccessibilityGas Piping Gas Pressure TestingGAS Supply Gas RequirementsGas Pipe Capacity Table Minimum Btuh Input Combustion AIR & VentilationUnconfined Space Confined SpaceAll Air from Inside the Building All Air from OutdoorsLouvers and Grilles Vent Pipe System Draft Hood InstallationVertical Exhaust Gas Vent Vent ConnectorsVent Pipe Size Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveDischarge Line Temperature & Pressure Relief ValveRelief Valve and Pipe Insulation Combination Space Heating/Potable Water SystemSolar Installation Wiring DiagramElectrical Connections Important Information about this Water Heater Installation ChecklistOperating Instructions Operating Your Water HeaterWater Heater Operation Checking the DraftBurn Hazard Water Temperature Regulation Burner FlamesEmergency Shut Down Water Heater Sounds Safety Shut-offOperational Conditions CondensationRoutine Preventive Maintenance Powered Anode OperationDraining and Flushing Removing the Burner from the Manifold/ Burner Assembly Maintenance of Your Water HeaterReplacement Parts Removing the Manifold/Burner AssemblyReplacing the Flame Sense/Hot Surface igniter Assembly Cleaning the Combustion Chamber and Air Diverter AssemblyReplacing the Manifold/Burner Assembly Removing and Replacing the Gas Control Valve/Thermostat Removing the Gas Control Valve/ThermostatReplacing the Gas Valve Troubleshooting Chart Pressurized Combustion Chamber System Operational ChecklistCont Control Display Status Problem Solution Control Display TroubleshootingControl Display Status Problem Solution FV-SENSE and Open Flashing YES Troubleshooting FlowchartRepair Parts Illustration Repair Parts ListListed Parts Kits and Illustrations Page Page Page Year Limited Residential GAS WarrantyImportant Information

317998-002, GP 6 50YPC T 100, GP 6 40YPC T 100 specifications

State Industries has long been at the forefront of technological advancements and innovative design in the industrial market. The company has developed a range of high-efficiency products designed for various applications, including the GP 6 40YPC T 100 and GP 6 50YPC T 100 models, as well as the 317998-002 component. Each product in this lineup is characterized by specific features and cutting-edge technologies tailored to meet diverse operational needs.

The GP 6 40YPC T 100 model boasts a robust construction aimed at durability and resilience in demanding environments. Its design incorporates advanced materials that resist wear and corrosion, ensuring a prolonged lifespan and reduced maintenance requirements. The model operates efficiently even in high-pressure scenarios, making it suitable for various industrial applications, including manufacturing and processing.

In contrast, the GP 6 50YPC T 100 model is designed with a focus on maximizing performance and energy efficiency. It features an optimized airflow system that enhances heat dissipation, preventing overheating and maintaining operational integrity. This model is ideal for applications that require continuous operation, as it minimizes downtime and maximizes productivity. Additionally, the GP 6 50YPC T 100 is equipped with smart technology that monitors performance metrics, providing real-time feedback on operational efficiency.

The 317998-002 component serves as a critical element in both models, acting as a versatile interface that integrates seamlessly with existing systems. It is designed to enhance connectivity and facilitate communication between various industrial components, promoting improved efficiency and ease of integration.

Both the GP 6 models and the 317998-002 feature user-friendly interfaces, allowing operators to easily manage and adjust settings. This focus on user experience helps to reduce training time and improve overall operational efficiency. Furthermore, both models adhere to strict industry standards, ensuring reliability and safety in all conditions.

In summary, State Industries' GP 6 40YPC T 100 and GP 6 50YPC T 100 models, along with the 317998-002 component, represent the pinnacle of innovation and reliability in industrial solutions. Their advanced features, technologies, and characteristics make them suitable choices for organizations looking to enhance productivity and operational efficiency in a variety of applications. With a commitment to quality and performance, State Industries continues to set the standard for excellence in the industry.