A listed temperature and pressure relief valve of adequate capacity is installed on the heater. The locations shown in the installation diagrams on the following pages are typical.

The discharge opening of the temperature and pressure relief valve must be piped to an open drain and should not be subject to freezing conditions. DO NOT REDUCE, BLOCK OR PLUG THE DISCHARGE OPENING OF THE VALVE.

TWO TEMPERATURE - TWO HEATERS, ONE PRE-HEATER/ONE - BOOSTER HEATER

WITH OR WITHOUT BUILDING RECIRCULATION

DANGER

INSERT A

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES. SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 27. IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT,ADDAN ANTI- SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES.

CIRCULATING RETURN LINE CONNECTIONS

-FROM FIXTURE LOOP, IF USED, CONNECTTO PREHEATER INLET.

-FROM BOOSTED TEMPERATURE LOOP, IF USED CONNECTTO BOOSTER INLET.

†AVAILABLE FROM STATE WATER HEATERS. *PIPE RELIEF VALVE TO OPEN DRAIN.

INSTALL IN ACCORDANCE WITH LOCALCODES.

18

Image 18
Contents Models SBD71120NE Thru SBD85500NE ROUGH-IN-DIMENSIONS Canadian Standard Sandblaster BHeater Performance Datasbd Models Heater Performance Datasbd CGA ModelsTable of Contents General Safety InformationForeword Improper Combustion High Altitude InstallationsChemical Vapor Corrosion Liquid Petroleum ModelsHigh Limit Switch E.C.O FeaturesSELF-CLEANING Hydro Cannon RequirementsCirculating Pump Electronic Ignition ControlAutomatic Flue Damper Device Dishwashing Machine RequirementLeveling ClearancesHard Water AIR RequirementsVent Reducer Water Potable Heating Space Heating VentingMultiple Heater Manifold Relief ValveType B GAS Vent ModelTechnical Data VENTING, Table GAS Pipingand Dirt LEG Installation GAS PipingGrounding Instructions GAS Pressure RegulatorGAS Meter Size Natural Gases only General Installation DIAGRAMS-TOP INLET/OUTLET UsageTube Inlet Installation Code RestrictionsVertical Storage Tank and Forced Circulation Horizontal Storage Tank and Forced CirculationInsert a Installation DIAGRAMS-SIDE INLET/OUTLET Usage Heater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Vertical Storage Tank Horizontal Storage TankManifold Kits TWO Unit Manifold KIT Three Unit Manifold KITFour Unit Manifold KIT Multiple Unit Installations Single Unit InstallationVent Installation Mechanical VentingOperation FillingPurging For Your Safety Read Before Operating OperatingTo Turn OFF GAS to Appliance For Your Safety Read Before Operating Testing Damper Operation Water Temperature ControlAdjustments Checking VentingCheck the Pilot Preventive MaintenancePilot Burner Assembly Main Burner Pilot BurnerGAS Valves Checking the InputTypical Pilot and Main Burner Flames Anode ROD Inspection Remote Storage Tank Temperature ControlVenting System HOT Water OdorTank Cleanout Procedure Deliming Using FLO-JUG MethodDeliming Solvents Replacement Parts ServiceTroubleshooting Ignition Module System Electrical ServicingAbnormal Operation Effikal RVGP-KSF-SERIES Flue Damper Trouble Shooting GuideNormal Sequence of Operation PIN END ViewOperational Checklist Complaint Cause Remedy User ServicemanPage Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

THRU SBD85500NE, SBD71120NE specifications

State Industries' SBD71120NE and SBD85500NE are innovative water heaters designed to deliver superior performance and efficiency for residential and commercial applications. These models are part of State Industries' commitment to providing reliable and durable products that meet the diverse needs of consumers.

The SBD71120NE features a capacity of 71 gallons, making it an ideal choice for households with high hot water demand. This model is equipped with advanced insulation technology that minimizes heat loss, ensuring energy efficiency and cost savings over time. With its high energy factor rating, the SBD71120NE not only meets but exceeds the stringent energy efficiency standards set by the Department of Energy. The unit is powered by natural gas, providing quick heating capabilities and a reliable source of hot water when needed.

In contrast, the SBD85500NE has a larger capacity of 85 gallons, catering to larger households or commercial settings with increased hot water requirements. This unit also employs advanced insulation materials that contribute to reduced operating costs and enhanced thermal efficiency. The SBD85500NE utilizes a high-performance power vent system, which facilitates efficient venting of combustion gases and allows for flexible installation options.

Both models are equipped with modern controls, providing users with easy access to temperature settings and diagnostics. The straightforward digital display allows for intuitive adjustments, ensuring optimal water temperature while promoting safety. Furthermore, both units come with a robust warranty, reflecting State Industries' confidence in the durability and longevity of their products.

One of the standout features of the SBD71120NE and SBD85500NE is their compatibility with smart home technology. Integrating these units with a smart thermostat enables users to monitor and manage their hot water usage remotely, thus contributing to more efficient energy consumption.

In conclusion, the State Industries SBD71120NE and SBD85500NE represent cutting-edge technologies and superior craftsmanship. Their respective sizes and capacities make them suitable options for a variety of applications, ensuring reliable hot water delivery while promoting energy efficiency and cost savings. With their advanced features and solid construction, these water heaters are designed to stand the test of time, providing homeowners and businesses with peace of mind and satisfaction.