State Industries THRU SBD85500NE Electronic Ignition Control, Automatic Flue Damper Device

Page 7

Continued pilot outage preceded by higher than usual water temperature is evidence of high limit switch operation. Contact your dealer or servicer to determine the reason for operation.

ELECTRONIC IGNITION CONTROL

Each heater is equipped with a Honeywell ignition module. The solid state ignition control, fig. 4, ignites the pilot burner gas by creating a spark at the pilot assembly. Pilot gas is ignited and burns during each running cycle. The main burner and pilot gases are cut off during the OFF cycle. Pilot gas ignition is proven by the pilot sensor. Main burner ignition will not occur if the pilot sensor does not first sense pilot ignition.

HONEYWELL IGNITION MODULE

S8600M Continuous Re-Try

FIGURE4

AUTOMATIC FLUE DAMPER DEVICE

All units are equipped with an automatic flue damper that reduces heat loss during the OFF cycles. The automatic flue damper drive assembly is a field replaceable part and may be obtained by contacting State Water Heaters.

Each automatic flue damper drive assembly is equipped with a “Service Switch”, as shown in figure 5.

FIGURE5

The “Service Switch” has 2 positions: AUTOMATIC OPERATION and HOLD OPEN DAMPER. For normal operation the switch should be in the AUTOMATIC OPERATION position.

If there is a problem with the damper the “Service Switch” can be placed in the HOLD OPEN DAMPER position. When the switch is placed in the HOLD OPEN DAMPER position the damper disc will rotate to the open position and the heater may be used until vent assembly is repaired or replaced. DO NOT turn the damper disc manually; damage will occur to the drive assembly if operated manually. Refer to TESTING DAMPER OPERATION section of this manual for additional information.

CIRCULATING PUMP

A circulating pump is used when a system requires a circulating loop or there is a storage tank used in conjunction with the heater. Refer to the piping diagrams in this manual for electrical hookup information and install in accordance with the latest version of the National Electric Code ANSI/NFPA No. 70. For Canada refer to Canadian Code CSA C22.1.

Only all bronze circulators should be used with commercial water heaters.

Although circulators are oiled and operated by the manufacturer some circulators must be oiled again before operating. Please refer to manufacturer’s instructions.

DISHWASHING MACHINE REQUIREMENT

These appliances meet the National Sanitation Foundation Standard for sanitary installations when used with the following leg kits, Part No’s. 6570-0 and 6570-7.

All dishwashing machines meeting the National Sanitation Foundation requirements are designed to operate with water flow pressures between 15 and 25 psi (103 Kpa and 173 Kpa). Flow pressures above 25 psi (173 Kpa), or below 15 psi (103 Kpa), will result in improperly sanitized dishes. Where pressures are high, a water pressure reducing or flow regulating control valve should be used in 180°F (82°C) line to the dishwashing machine, and should be adjusted to deliver water between these limits.

The National Sanitation Foundation also recommends circulation of 180°F (82°C) water. Where this is done, the circulation should be very gentle so that it does not cause any unnecessary turbulence inside the water heater. The circulation should be just enough to provide 180°F (82°C) water at the point of take-off to the dishwashing machine. Adjust flow by means of the plug cock in the circulating line.

INSTALLATION INSTRUCTIONS

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING, AIR SUPPLY, VENTING, GAS SUPPLY AND ELECTRICAL WORK ARE REQUIRED.

WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

UNCRATING

The heater is shipped with the flue damper already installed. The wiring conduit runs from the thermostat to the damper drive cover. Before turning unit on, check to make sure the wiring conduit is securely plugged into damper drive.

LOCATING THE HEATER

When installing the heater, consideration must be given to proper location. Location selected should be as close to the stack or chimney as practicable, with adequate air supply and as centralized with the piping system as possible.

7

Image 7
Contents Models SBD71120NE Thru SBD85500NE Canadian Standard Sandblaster B ROUGH-IN-DIMENSIONSHeater Performance Datasbd CGA Models Heater Performance Datasbd ModelsGeneral Safety Information Table of ContentsForeword Liquid Petroleum Models High Altitude InstallationsChemical Vapor Corrosion Improper CombustionRequirements FeaturesSELF-CLEANING Hydro Cannon High Limit Switch E.C.ODishwashing Machine Requirement Electronic Ignition ControlAutomatic Flue Damper Device Circulating PumpClearances LevelingAIR Requirements Hard WaterVent Reducer Relief Valve VentingMultiple Heater Manifold Water Potable Heating Space HeatingModel Type B GAS VentTechnical Data VENTING, Table GAS Piping GAS Pipingand Dirt LEG InstallationGAS Pressure Regulator Grounding InstructionsGAS Meter Size Natural Gases only Code Restrictions Installation DIAGRAMS-TOP INLET/OUTLET UsageTube Inlet Installation GeneralHorizontal Storage Tank and Forced Circulation Vertical Storage Tank and Forced CirculationInsert a Installation DIAGRAMS-SIDE INLET/OUTLET Usage Heater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Horizontal Storage Tank Vertical Storage TankTWO Unit Manifold KIT Three Unit Manifold KIT Manifold KitsFour Unit Manifold KIT Mechanical Venting Single Unit InstallationVent Installation Multiple Unit InstallationsFilling OperationPurging Operating For Your Safety Read Before OperatingTo Turn OFF GAS to Appliance For Your Safety Read Before Operating Checking Venting Water Temperature ControlAdjustments Testing Damper OperationPilot Burner Preventive MaintenancePilot Burner Assembly Main Burner Check the PilotChecking the Input GAS ValvesTypical Pilot and Main Burner Flames HOT Water Odor Remote Storage Tank Temperature ControlVenting System Anode ROD InspectionDeliming Using FLO-JUG Method Tank Cleanout ProcedureDeliming Solvents Electrical Servicing ServiceTroubleshooting Ignition Module System Replacement PartsPIN END View Effikal RVGP-KSF-SERIES Flue Damper Trouble Shooting GuideNormal Sequence of Operation Abnormal OperationComplaint Cause Remedy User Serviceman Operational ChecklistPage Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

THRU SBD85500NE, SBD71120NE specifications

State Industries' SBD71120NE and SBD85500NE are innovative water heaters designed to deliver superior performance and efficiency for residential and commercial applications. These models are part of State Industries' commitment to providing reliable and durable products that meet the diverse needs of consumers.

The SBD71120NE features a capacity of 71 gallons, making it an ideal choice for households with high hot water demand. This model is equipped with advanced insulation technology that minimizes heat loss, ensuring energy efficiency and cost savings over time. With its high energy factor rating, the SBD71120NE not only meets but exceeds the stringent energy efficiency standards set by the Department of Energy. The unit is powered by natural gas, providing quick heating capabilities and a reliable source of hot water when needed.

In contrast, the SBD85500NE has a larger capacity of 85 gallons, catering to larger households or commercial settings with increased hot water requirements. This unit also employs advanced insulation materials that contribute to reduced operating costs and enhanced thermal efficiency. The SBD85500NE utilizes a high-performance power vent system, which facilitates efficient venting of combustion gases and allows for flexible installation options.

Both models are equipped with modern controls, providing users with easy access to temperature settings and diagnostics. The straightforward digital display allows for intuitive adjustments, ensuring optimal water temperature while promoting safety. Furthermore, both units come with a robust warranty, reflecting State Industries' confidence in the durability and longevity of their products.

One of the standout features of the SBD71120NE and SBD85500NE is their compatibility with smart home technology. Integrating these units with a smart thermostat enables users to monitor and manage their hot water usage remotely, thus contributing to more efficient energy consumption.

In conclusion, the State Industries SBD71120NE and SBD85500NE represent cutting-edge technologies and superior craftsmanship. Their respective sizes and capacities make them suitable options for a variety of applications, ensuring reliable hot water delivery while promoting energy efficiency and cost savings. With their advanced features and solid construction, these water heaters are designed to stand the test of time, providing homeowners and businesses with peace of mind and satisfaction.