State Industries SBD71120NE warranty Table of Contents, Foreword, General Safety Information

Page 4

TABLE OF CONTENTS

 

Page

ROUGH-IN-DIMENSIONS

2-3

TABLE OF CONTENTS

4

FOREWORD

4

GENERAL SAFETY INFORMATION

4-5

Chemical Vapor Corrosion

5

Improper Combustion

5

Liquid Petroleum Models

5

Extended Non-Use Periods

5

Insulation Blankets

5-6

High Altitude Installation

6

FEATURES

6

Self-Cleaning Hydro Cannon

6

High Limit Switch (E.C.O.)

6

Electronic Ignition Control

7

Automatic Flue Damper Device

7

Circulating Pump

7

Dishwashing Machine Requirement

7

INSTALLATION INSTRUCTIONS

7

Uncrating

7

Locating The Heater

8

Levelling

8

Clearances

8

Hard Water

8

Air Requirements

8-9

Unconfined Space

9

Confined Space

9

Vent Reducer

9

Venting

9-10

Multiple Heater Manifold

10

Water Line Connections

10

Water (Potable) Heating and Space Heating

10

Thermometers (Not Supplied)

10

Relief Valve

10

Technical Data Venting

11-12

Gas Piping

13-14

Gas Pressure Regulator

14

Heater Wiring

14

FOREWORD

These designs comply with ANSI Z21.10.3/CSA 4.3 M98 as an automatic circulating or automatic storage tank type water heater.

Heaters having an input of 305,000 (89 kWh), 365,000 (107 kWh), 399,000 (117 kWh) and 500,000 (147 kWh) Btuh with a recovery rating of 277.3 gph (1049 Lph) or more also comply with ANSI Z21.10.3 as an automatic instantaneous type heater.

Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and methods of piping necessary. It is highly essential that all water, gas piping and wiring be installed as shown on the diagrams.

Particular attention should be given to the installation of thermometers at the locations indicated on the diagrams as these are necessary for checking the proper functioning of the heater.

The heater is designed to operate on natural or propane gases. HOWEVER, MAKE SURE the gas on which the heater will operate is the same as that specified on the heater model and rating plate.

These heaters may be installed on combustible floors. Refer to LOCATING THE HEATER and INSTALLATION ON COMBUSTIBLE FLOORING sections for details.

 

Page

INSTALLATION DIAGRAMS

15-21

MANIFOLDS

22

MECHANICAL VENTING

23

Single Unit Installation

23

Vent Installation

23

Multiple Unit Installation

23

OPERATION

24

General

24

Filling

24

Purging

24

Lighting and Operating Labels

25-26

Water Temperature Control

27

Testing Damper Control

27

Checking Venting

27-28

PREVENTIVE MAINTENANCE

28

Check The Pilot

28

Pilot Burner

28

Main Burner

28-29

Gas Valves

29

Checking The Input

29

Venting System

30

Remote Storage Tank Temperature Control

30

Relief Valve

30

Hot Water Odor

30

Anode Rod Inspection

30

Recommended Procedure For Periodic Removal

 

of Lime Deposits From Tank Type Commercial

 

Water Heaters

30-31

Deliming Solvents

31

Tank Cleanout Procedures

31-32

Troubleshooting Ignition Module System

32

SERVICE

32

Electrical Servicing

32

Replacement Parts

32

Effikal Flue Damper Troubleshooting Guide

33

Operational Checklist

34

LIMITED WARRANTY

Insert

In addition to these instructions, the equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.

The installation must conform to these instructions and the local code authority having jurisdiction. In the absence of local codes, the installation must comply with the latest editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the National Electrical Code, NFPA 70, CAN/CSA B149.1-00, and CSA 2 C22.1. The former is available from the Canadian Standards Association, 8501 East Pleasant Valley Road, Cleveland, OH 44131, and both documents are available from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

GENERAL SAFETY

INFORMATION

PRECAUTIONS

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

4

Image 4
Contents Models SBD71120NE Thru SBD85500NE ROUGH-IN-DIMENSIONS Canadian Standard Sandblaster BHeater Performance Datasbd Models Heater Performance Datasbd CGA ModelsGeneral Safety Information Table of ContentsForeword High Altitude Installations Chemical Vapor CorrosionImproper Combustion Liquid Petroleum ModelsFeatures SELF-CLEANING Hydro CannonHigh Limit Switch E.C.O RequirementsElectronic Ignition Control Automatic Flue Damper DeviceCirculating Pump Dishwashing Machine RequirementLeveling ClearancesAIR Requirements Hard WaterVent Reducer Venting Multiple Heater ManifoldWater Potable Heating Space Heating Relief ValveType B GAS Vent ModelTechnical Data VENTING, Table GAS Pipingand Dirt LEG Installation GAS PipingGAS Pressure Regulator Grounding InstructionsGAS Meter Size Natural Gases only Installation DIAGRAMS-TOP INLET/OUTLET Usage Tube Inlet InstallationGeneral Code RestrictionsVertical Storage Tank and Forced Circulation Horizontal Storage Tank and Forced CirculationInsert a Installation DIAGRAMS-SIDE INLET/OUTLET Usage Heater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Vertical Storage Tank Horizontal Storage TankTWO Unit Manifold KIT Three Unit Manifold KIT Manifold KitsFour Unit Manifold KIT Single Unit Installation Vent InstallationMultiple Unit Installations Mechanical VentingFilling OperationPurging Operating For Your Safety Read Before OperatingTo Turn OFF GAS to Appliance For Your Safety Read Before Operating Water Temperature Control AdjustmentsTesting Damper Operation Checking VentingPreventive Maintenance Pilot Burner Assembly Main BurnerCheck the Pilot Pilot BurnerChecking the Input GAS ValvesTypical Pilot and Main Burner Flames Remote Storage Tank Temperature Control Venting SystemAnode ROD Inspection HOT Water OdorDeliming Using FLO-JUG Method Tank Cleanout ProcedureDeliming Solvents Service Troubleshooting Ignition Module SystemReplacement Parts Electrical ServicingEffikal RVGP-KSF-SERIES Flue Damper Trouble Shooting Guide Normal Sequence of OperationAbnormal Operation PIN END ViewOperational Checklist Complaint Cause Remedy User ServicemanPage Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

THRU SBD85500NE, SBD71120NE specifications

State Industries' SBD71120NE and SBD85500NE are innovative water heaters designed to deliver superior performance and efficiency for residential and commercial applications. These models are part of State Industries' commitment to providing reliable and durable products that meet the diverse needs of consumers.

The SBD71120NE features a capacity of 71 gallons, making it an ideal choice for households with high hot water demand. This model is equipped with advanced insulation technology that minimizes heat loss, ensuring energy efficiency and cost savings over time. With its high energy factor rating, the SBD71120NE not only meets but exceeds the stringent energy efficiency standards set by the Department of Energy. The unit is powered by natural gas, providing quick heating capabilities and a reliable source of hot water when needed.

In contrast, the SBD85500NE has a larger capacity of 85 gallons, catering to larger households or commercial settings with increased hot water requirements. This unit also employs advanced insulation materials that contribute to reduced operating costs and enhanced thermal efficiency. The SBD85500NE utilizes a high-performance power vent system, which facilitates efficient venting of combustion gases and allows for flexible installation options.

Both models are equipped with modern controls, providing users with easy access to temperature settings and diagnostics. The straightforward digital display allows for intuitive adjustments, ensuring optimal water temperature while promoting safety. Furthermore, both units come with a robust warranty, reflecting State Industries' confidence in the durability and longevity of their products.

One of the standout features of the SBD71120NE and SBD85500NE is their compatibility with smart home technology. Integrating these units with a smart thermostat enables users to monitor and manage their hot water usage remotely, thus contributing to more efficient energy consumption.

In conclusion, the State Industries SBD71120NE and SBD85500NE represent cutting-edge technologies and superior craftsmanship. Their respective sizes and capacities make them suitable options for a variety of applications, ensuring reliable hot water delivery while promoting energy efficiency and cost savings. With their advanced features and solid construction, these water heaters are designed to stand the test of time, providing homeowners and businesses with peace of mind and satisfaction.