FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLYA FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.THIS APPLIANCE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.

B.BEFORE OPERATING SMELL ALL AROUND THE APPLIANCE AREA FOR GAS . BE SURE TO SMELL NEXT TO THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN AIR AND WILL SETTLE ON THE FLOOR.

WHAT TO DO IF YOU SMELL GAS

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRIC SWITCH

DO NOT USE ANY PHONE IN YOUR BUILDING.

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE. FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER,

CALL THE FIRE DEPARTMENT.

C.USE ONLY YOUR HAND TO PUSH IN OR TURN THE GAS CONTROL KNOB . NEVER USE TOOLS. IF THE KNOB WILL NOT PUSH IN OR TURN BY HAND, DON’T TRY TO REPAIR IT. CALL A QUALIFIED SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE OR EXPLOSION.

D.DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

E.DO NOT OPERATE APPLIANCE UNLESS UNIT IS FILLED WITH WATERAND INLET LINES AFTER FULLY OPEN.

 

 

 

OPERATING

 

 

1.

 

STOP! READ THE SAFETY INFORMATION ON

 

 

 

 

 

 

THIS LABEL.

 

 

 

 

2.

TURN “OFF “ ALL ELECTRICAL POWER TO THE

 

 

 

 

 

APPLIANCE. THE FLUE DAMPER WILL

 

 

 

 

 

AUTOMATICALLY SPRING TO “OPEN” POSITION

 

 

 

 

3.

THIS APPLIANCE IS EQUIPPED WITH AN IGNITION

 

 

 

 

 

DEVICE WHICH AUTOMATICALLY LIGHTS THE

 

 

 

 

 

PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.

 

 

 

 

 

 

 

 

7.

TURN GAS CONTROL TOP KNOB

4.

REFER TO THE DIAGRAMS ABOVE. TURN TOP

 

COUNTERCLOCKWISE

TO “ON” POSITION,

 

KNOB OF THE GAS CONTROL VALVE CLOCKWISE

 

DO NOT FORCE KNOB.

 

 

 

TO “OFF” POSITION (FIG. A).

8.

TURN ON ALL ELECTRICAL POWER TO THE

 

 

 

 

5.

REMOVE THERMOSTAT CONTROL COVER. ROTATE

 

APPLIANCE.

 

9.

ROTATE APPLIANCE THERMOSTAT DIAL BY HAND

 

THERMOSTAT DIAL-BY HAND-COUNTERCLOCK-

 

WISE

TO LOWEST SETTING. DO NOT FORCE

 

DESIRED SETTING. DO NOT FORCE. FLUE DAMPER

 

 

WILL “OPEN” AND PILOT IGNITION WILL OCCUR.

 

DIAL OR MECHANICAL STOP.

 

 

 

WHEN PILOT IGNITION IS SENSED, THE MAIN

 

 

 

 

 

6.

WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS .

 

BURNER(S) WILL IGNITE.

 

10.

REPLACE THERMOSTAT CONTROL COVER.

 

IF YOU THEN SMELL GAS:

 

 

STOP! FOLLOW “B” IN THE SAFETY

11.

IF THE APPLIANCE WILL NOT OPERATE, FOLLOW

 

 

 

THE INSTRUCTIONS “TO TURN OFF GAS

 

 

INFORMATION ABOVE IN THIS LABEL.

 

TO APPLIANCE” AND CALL YOUR SERVICE

 

IF YOU DON’T SMELL GAS. GO TO NEXT STEP.

 

TECHNICIAN OR GAS SUPPLIER.

 

 

 

 

 

 

 

 

TO TURN OFF GAS TO APPLIANCE

1.ROTATE THERMOSTAT DIAL -BY HAND- COUNTERCLOCKWISE TO LOWEST SETTING. SEE STEP 5 ABOVE.

2.TURN OFF ALL ELECTRICAL POWER TO THE APPLIANCE IF SERVICE IS TO BE PERFORMED.

3.REMOVE CONTROL ACCESS PANEL.

4. TURN KNOB OF GAS CONTROL VALVE CLOCKWISE

TO “OFF” POSITION. SEE STEP 4 ABOVE AND

DIAGRAMS.

 

5.REPLACE CONTROL ACCESS COVERS (SEE STEP 10 ABOVE).

25

Image 25
Contents Models SBD71120NE Thru SBD85500NE Canadian Standard Sandblaster B ROUGH-IN-DIMENSIONSHeater Performance Datasbd CGA Models Heater Performance Datasbd ModelsGeneral Safety Information Table of ContentsForeword Chemical Vapor Corrosion High Altitude InstallationsImproper Combustion Liquid Petroleum ModelsSELF-CLEANING Hydro Cannon FeaturesHigh Limit Switch E.C.O RequirementsAutomatic Flue Damper Device Electronic Ignition ControlCirculating Pump Dishwashing Machine RequirementClearances LevelingAIR Requirements Hard WaterVent Reducer Multiple Heater Manifold VentingWater Potable Heating Space Heating Relief ValveModel Type B GAS VentTechnical Data VENTING, Table GAS Piping GAS Pipingand Dirt LEG InstallationGAS Pressure Regulator Grounding InstructionsGAS Meter Size Natural Gases only Tube Inlet Installation Installation DIAGRAMS-TOP INLET/OUTLET UsageGeneral Code RestrictionsHorizontal Storage Tank and Forced Circulation Vertical Storage Tank and Forced CirculationInsert a Installation DIAGRAMS-SIDE INLET/OUTLET Usage Heater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Horizontal Storage Tank Vertical Storage TankTWO Unit Manifold KIT Three Unit Manifold KIT Manifold KitsFour Unit Manifold KIT Vent Installation Single Unit InstallationMultiple Unit Installations Mechanical VentingFilling OperationPurging Operating For Your Safety Read Before OperatingTo Turn OFF GAS to Appliance For Your Safety Read Before Operating Adjustments Water Temperature ControlTesting Damper Operation Checking VentingPilot Burner Assembly Main Burner Preventive MaintenanceCheck the Pilot Pilot BurnerChecking the Input GAS ValvesTypical Pilot and Main Burner Flames Venting System Remote Storage Tank Temperature ControlAnode ROD Inspection HOT Water OdorDeliming Using FLO-JUG Method Tank Cleanout ProcedureDeliming Solvents Troubleshooting Ignition Module System ServiceReplacement Parts Electrical ServicingNormal Sequence of Operation Effikal RVGP-KSF-SERIES Flue Damper Trouble Shooting GuideAbnormal Operation PIN END ViewComplaint Cause Remedy User Serviceman Operational ChecklistPage Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

THRU SBD85500NE, SBD71120NE specifications

State Industries' SBD71120NE and SBD85500NE are innovative water heaters designed to deliver superior performance and efficiency for residential and commercial applications. These models are part of State Industries' commitment to providing reliable and durable products that meet the diverse needs of consumers.

The SBD71120NE features a capacity of 71 gallons, making it an ideal choice for households with high hot water demand. This model is equipped with advanced insulation technology that minimizes heat loss, ensuring energy efficiency and cost savings over time. With its high energy factor rating, the SBD71120NE not only meets but exceeds the stringent energy efficiency standards set by the Department of Energy. The unit is powered by natural gas, providing quick heating capabilities and a reliable source of hot water when needed.

In contrast, the SBD85500NE has a larger capacity of 85 gallons, catering to larger households or commercial settings with increased hot water requirements. This unit also employs advanced insulation materials that contribute to reduced operating costs and enhanced thermal efficiency. The SBD85500NE utilizes a high-performance power vent system, which facilitates efficient venting of combustion gases and allows for flexible installation options.

Both models are equipped with modern controls, providing users with easy access to temperature settings and diagnostics. The straightforward digital display allows for intuitive adjustments, ensuring optimal water temperature while promoting safety. Furthermore, both units come with a robust warranty, reflecting State Industries' confidence in the durability and longevity of their products.

One of the standout features of the SBD71120NE and SBD85500NE is their compatibility with smart home technology. Integrating these units with a smart thermostat enables users to monitor and manage their hot water usage remotely, thus contributing to more efficient energy consumption.

In conclusion, the State Industries SBD71120NE and SBD85500NE represent cutting-edge technologies and superior craftsmanship. Their respective sizes and capacities make them suitable options for a variety of applications, ensuring reliable hot water delivery while promoting energy efficiency and cost savings. With their advanced features and solid construction, these water heaters are designed to stand the test of time, providing homeowners and businesses with peace of mind and satisfaction.