State Industries THRU SBD85500NE, SBD71120NE warranty GAS Valves, Checking the Input

Page 29

TYPICAL PILOT AND MAIN BURNER FLAMES

FIGURE16

If the preceding burner characteristics are not evident, check for accumulation of lint or other foreign material that restricts or blocks the air openings to the burner or heater.

NOTE: Cleaning of main burners.

1.Remove main burners from unit.

2.Check that burner venturi and ports are free of foreign matter.

3.Clean burners with bristle brush and/or vacuum cleaner — DO NOT distort burner ports or pilot location.

4.Reinstall burners in unit. Make sure front and rear of burners are installed correctly in burner support brackets.

Also check for good flow of combustion and ventilating air to the unit. Maintain a clear area around the heater at all times.

GAS VALVES

Figure 16 shows the two types of combination gas control valves used on these heaters.

FIGURE16

If the gas valve becomes defective, repairs should not be attempted. A new valve should be installed in place of the defective one.

CHECKING THE INPUT

For appliance installation locations with elevations above 2000 feet (610 m), refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input reduction procedure.

1.Attach a pressure gauge or a manometer to the gauge port and refer to Table 5, for correct manifold pressure.

2.Use this formula to “clock” the meter. Be sure that other gas consuming appliances are not operating during this interval.

3600 X H = Btuh

T

T= Time in seconds to burn one cubic foot of gas. H = Btu’s per cubic foot of gas.

Btuh = Actual heater input.

Example: (Using SBD-240 heater)

T= 15.8 seconds H = 1050 Btu Btuh = ?

36.8X 1050 = 240,000 Btuh (70.3 kWh) (Compare with

15.9heater model and rating)

Should it be necessary to adjust the gas pressure to the burners to obtain the full input rate, the steps below should be followed:

3.Remove the regulator adjustment sealing cap, fig. 17, and adjust the pressure by turning the adjusting screw with a screwdriver.

Clockwise to increase gas pressure and input rate.

Counterclockwise to decrease gas pressure and input rate.

4.“Clock” the meter as in step 2 above.

5.Repeat steps 3 and 4 until the specified input rate is achieved.

6.Turn the gas control knob to PILOT. Remove the pressure gauge and replace the sealing cap and the allen wrench set screw in the pressure tap opening.

WARNING

UNDER NO CIRCUMSTANCES SHOULD THE GAS INPUT EXCEED THE INPUT SHOWN ON THE HEATER MODEL AND RATING PLATE. OVERFIRING COULD RESULT IN DAMAGE OR SOOTING OF THE HEATER.

When the heater is operating at full capacity, or full gas input, it should consume 1 cu. ft. of gas in time indicated on Table 6.

29

Image 29
Contents Models SBD71120NE Thru SBD85500NE Canadian Standard Sandblaster B ROUGH-IN-DIMENSIONSHeater Performance Datasbd CGA Models Heater Performance Datasbd ModelsForeword Table of ContentsGeneral Safety Information Chemical Vapor Corrosion High Altitude InstallationsImproper Combustion Liquid Petroleum ModelsSELF-CLEANING Hydro Cannon FeaturesHigh Limit Switch E.C.O RequirementsAutomatic Flue Damper Device Electronic Ignition ControlCirculating Pump Dishwashing Machine RequirementClearances LevelingVent Reducer Hard WaterAIR Requirements Multiple Heater Manifold VentingWater Potable Heating Space Heating Relief ValveModel Type B GAS VentTechnical Data VENTING, Table GAS Piping GAS Pipingand Dirt LEG InstallationGAS Meter Size Natural Gases only Grounding InstructionsGAS Pressure Regulator Tube Inlet Installation Installation DIAGRAMS-TOP INLET/OUTLET UsageGeneral Code RestrictionsHorizontal Storage Tank and Forced Circulation Vertical Storage Tank and Forced CirculationInsert a Installation DIAGRAMS-SIDE INLET/OUTLET Usage Heater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Horizontal Storage Tank Vertical Storage TankFour Unit Manifold KIT Manifold KitsTWO Unit Manifold KIT Three Unit Manifold KIT Vent Installation Single Unit InstallationMultiple Unit Installations Mechanical VentingPurging OperationFilling To Turn OFF GAS to Appliance For Your Safety Read Before OperatingOperating For Your Safety Read Before Operating Adjustments Water Temperature ControlTesting Damper Operation Checking VentingPilot Burner Assembly Main Burner Preventive MaintenanceCheck the Pilot Pilot BurnerTypical Pilot and Main Burner Flames GAS ValvesChecking the Input Venting System Remote Storage Tank Temperature ControlAnode ROD Inspection HOT Water OdorDeliming Solvents Tank Cleanout ProcedureDeliming Using FLO-JUG Method Troubleshooting Ignition Module System ServiceReplacement Parts Electrical ServicingNormal Sequence of Operation Effikal RVGP-KSF-SERIES Flue Damper Trouble Shooting GuideAbnormal Operation PIN END ViewComplaint Cause Remedy User Serviceman Operational ChecklistPage Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

THRU SBD85500NE, SBD71120NE specifications

State Industries' SBD71120NE and SBD85500NE are innovative water heaters designed to deliver superior performance and efficiency for residential and commercial applications. These models are part of State Industries' commitment to providing reliable and durable products that meet the diverse needs of consumers.

The SBD71120NE features a capacity of 71 gallons, making it an ideal choice for households with high hot water demand. This model is equipped with advanced insulation technology that minimizes heat loss, ensuring energy efficiency and cost savings over time. With its high energy factor rating, the SBD71120NE not only meets but exceeds the stringent energy efficiency standards set by the Department of Energy. The unit is powered by natural gas, providing quick heating capabilities and a reliable source of hot water when needed.

In contrast, the SBD85500NE has a larger capacity of 85 gallons, catering to larger households or commercial settings with increased hot water requirements. This unit also employs advanced insulation materials that contribute to reduced operating costs and enhanced thermal efficiency. The SBD85500NE utilizes a high-performance power vent system, which facilitates efficient venting of combustion gases and allows for flexible installation options.

Both models are equipped with modern controls, providing users with easy access to temperature settings and diagnostics. The straightforward digital display allows for intuitive adjustments, ensuring optimal water temperature while promoting safety. Furthermore, both units come with a robust warranty, reflecting State Industries' confidence in the durability and longevity of their products.

One of the standout features of the SBD71120NE and SBD85500NE is their compatibility with smart home technology. Integrating these units with a smart thermostat enables users to monitor and manage their hot water usage remotely, thus contributing to more efficient energy consumption.

In conclusion, the State Industries SBD71120NE and SBD85500NE represent cutting-edge technologies and superior craftsmanship. Their respective sizes and capacities make them suitable options for a variety of applications, ensuring reliable hot water delivery while promoting energy efficiency and cost savings. With their advanced features and solid construction, these water heaters are designed to stand the test of time, providing homeowners and businesses with peace of mind and satisfaction.