State Industries SSED 5 instruction manual Alarm Output Setup Menu, Display Settings Menu

Page 27

ALARM OUTPUT SETUP MENU

Permits user to set the condition (from a list of options) for when the CCB’s integral alarm output relay will be energized. Alarm relay connections (common, normally open, normally closed) are located on the J3 terminal strip on the CCB - see wiring diagrams starting on page 12. Alarm output relay contacts are capable of switching 1 amp maximum at 120 VAC.

Alarm Output Settings

Changing the user settings in this menu is done using the same methods for changing the Operating Set Point.

Service Note: Adjustable user settings in the Alarm Output Setup menu are unaffected by Restore Factory Defaults.

The alarm relay operates in the background according to the settings in this menu and is not capable of disabling water heater operation. The alarm relay is used for external notification/verification of various operational conditions such as fault conditions and heating mode status. This relay can be used with building EMS (Energy Management System) and other external supervisory controls.

Output Function

Adjustable user setting. Available options for the Alarm Output Function setting are:

Heating Mode: Used for heating mode on/off status notification.

Enable / Disable Closed: Used for notification and/or verification of the enable/disable circuits open/closed status. There are two enable/ disable circuits available for external supervisory control(s) at the J7 socket on the CCB - see wiring diagrams. Enable/disable circuit(s) status can be viewed in the Heater Status Menu.

Temp < Heater SP: Used for external notification when current tank temperature drops below Operating Set Point.

Temp < Alarm SP: Used for external notification when current tank temperature drops below programmable Alarm SP.

Fault or Alert: Used for external notification whenever a Fault or Alert condition is active.

Fault: Used for notification whenever a Fault condition is active.

Disabled: Disables the Alarm Relay Output Function.

Alarm SP

Adjustable user setting (90°F to 190°F) the control system uses for the “Temp < Alarm SP” function described above. This setting has no effect with any other Alarm Output functions.

DISPLAY SETTINGS MENU

Permits user to set display options for viewing information on the UIM’s LCD screen.

Temperature Units

Adjustable user setting that changes temperature units display to Celsius °C or Fahrenheit °F.

Backlight Delay

Adjustable user setting that determines how long the UIM’s LCD backlight remains illuminated after a key has been pressed. Available settings are; Always Off, 10, 30 or 60 seconds and Always On.

Contrast

Adjustable user setting to adjust the UIM’s LCD screen contrast between text and background.

Display Settings

Changing the user settings in this menu is done using the same methods for changing the Operating Set Point.

Service Note: Adjustable user settings in the Display Settings menu are unaffected by Restore Factory Defaults.

WATER HEATER INFORMATION MENU

This menu displays non adjustable operational information.

Top of Menu

27

Image 27
Contents Asme Installation Operation Service Maintenance Limited WarrantyQualified Installer or Service Agency Safe INSTALLATION, USE and ServiceGeneral Safety Information Precautions Hydrogen GAS FlammableGrounding Instructions Introduction Table of ContentsSsed Dimensions and Capacities DataFeatures and Components Approvals Model and Rating Locating the NEW Water HeaterFacts to Consider About the Location General Installation RequirementsTemperature-Pressure Relief Valve Required AbilityWater Line Connections Closed Water SystemsThermal Expansion Heater Circuits Power CircuitElectrical Data Branch CircuitStandard KW Inputs 208-240V / 3-1PH Wiring DiagramsDiagram Small Commercial Wire Diagram 208-240V / 3PHDiagram Small Commercial Wire Diagram Single Phase Phase Conversions300-600V / 3PH DiagramDraining the Water Heater OperationFilling the Water Heater Initial Start UpThermostat Controls Temperature RegulationHigh Temperature Limit Controls ECO Temperature AdjustmentControl System Navigation Control System FeaturesControl System Operation Heating Element OperationStatus Icons Description Operating States Control System MenusMenus Description Temperatures Menu Action Temperature SettingsWater Heater Status Menu Economy Mode Setup MenuHeater In Economy Mode Daily Operating Mode Sun Mon Tue Wed Thu Fri SatCurrent Time Setpoint Adjustment Value Economy Mode SettingsTime Clock Settings Daily Operating Mode Settings Economy Mode All DayNormal Operation Between Alarm Output Setup Menu Display Settings MenuWater Heater Information Menu Current Fault / Alert Menu Fault History MenuFault Occurrence Menu Factory Defaults Restore Factory Defaults Restore Factory Defaults MenuFlushing MaintenanceTemperature-Pressure Relief Valve Operation Maintenance scheduleLime Scale Removal Process for Lime Scale Removal is AS FollowsOther Scale Removal Hard Water Troubleshooting ChecklistTank WarrantyPage Page Technical Support and Parts 800

SSED 5 specifications

State Industries, a prominent player in the heating and cooling sector, has unveiled its latest product, the SSED 5 series. This state-of-the-art water heater stands out in the market due to its unique features and advanced technologies designed to enhance efficiency, durability, and user-friendliness.

One of the key characteristics of the SSED 5 series is its innovative design. Constructed using high-quality materials, the unit is built to withstand the rigors of everyday usage while minimizing corrosion and wear. The external casing is both aesthetically pleasing and functional, providing adequate insulation to reduce heat loss, which in turn improves energy efficiency.

Energy-saving technologies are at the forefront of the SSED 5 series. It utilizes advanced heating elements that offer superior performance compared to traditional models. This includes a high thermal efficiency rating, allowing users to enjoy consistent hot water without incurring high utility bills. Moreover, the SSED 5 is equipped with integrated smart technology that enables users to monitor and control the unit remotely via a mobile app. This feature adds convenience and promotes energy conservation by allowing adjustments to be made according to real-time needs.

The SSED 5’s performance is further enhanced by its user-friendly digital control panel. This intuitive interface simplifies operation, allowing users to easily set their preferred water temperature and access diagnostic information. Safety features are also paramount, with built-in mechanisms to prevent overheating and leaks, ensuring peace of mind during operation.

Additionally, the SSED 5 series is notable for its environmental compliance. A commitment to sustainable practices is evident in its low emissions and energy-efficient operation, which contributes to reducing the overall carbon footprint.

In summary, the State Industries SSED 5 series represents a remarkable advancement in water heater technology. With its robust design, energy efficiency, smart technology integration, user-friendly interface, and safety features, it caters to modern consumers looking for reliable and effective heating solutions. As the demand for efficient and environmentally friendly products continues to rise, the SSED 5 is poised to meet and exceed market expectations. This makes it a leading choice for homeowners seeking innovation and quality in their hot water systems.