The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding tank, water ions attack and eat away the anode rod. This does not affect water’s taste or color. The rod must be maintained to keep tank in operating condition.
Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified technician, and at a minimum should be checked annually after the warranty period.
Temperature-Pressure Relief Valve Test
Explosion Hazard
Properly sized
Can result in overheating and excessive tank pressure.
Can cause serious injury or death.
DANGER
•Burn hazard.
•Hot water discharge.
•Keep clear of Temperature- Pressure Relief Valve discharge outlet.
DRAINING AND FLUSHING
It is recommended that the water heater storage tank be drained and flushed every 6 months to reduce sediment buildup. The water heater should be drained if being shut down during freezing temperatures. See Typical Installation section in this manual for location of the water heater components described below.
DANGER
• Burn hazard. |
It is recommended that the
When checking the
To check the relief valve, lift lever at the end of valve several times, see Figure 28. The valve should seat properly and operate freely.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater and drain the water heater, see Draining And Flushing on page 31. Replace the
TEMPERATURE-PRESSURE
RELIEF VALVE
DISCHARGE PIPE
Figure 28.
If the
Note: Excessive water pressure is the most common cause of
DO NOT PLUG THE
• | Hot water discharge. |
• | Keep hands clear of drain |
| valve discharge. |
TO DRAIN THE WATER HEATER STORAGE TANK:
1.Turn off the electrical supply to the water heater.
2.Turn off the gas supply at the Main Gas Shutoff Valve if the water heater is going to be shut down for an extended period.
3.Ensure the cold water inlet valve is open.
4.Open a nearby hot water faucet and let the water run until the water is no longer hot.
5.Close the cold water inlet valve to the water heater.
6.Connect a hose to the water heater drain valve and terminate it to an adequate drain.
7.Open the water heater drain valve and allow all the water to drain from the storage tank.
8.Close the water heater drain valve when all water in the storage tank has drained.
9.Close the hot water faucet opened in Step 4.
10.If the water heater is going to be shut down for an extended period, the drain valve should be left open.
TO FLUSH THE WATER HEATER STORAGE TANK:
11.Turn off the electrical supply to the water heater.
12.Ensure the cold water inlet valve is open.
13.Open a nearby hot water faucet and let the water run until the water is no longer hot. Then close the hot water faucet.
14.Connect a hose to drain valve and terminate it to an adequate drain.
15.Ensure the drain hose is secured before and during the entire flushing procedure. Flushing is performed with system water pressure applied to the water heater.
16.Open the water heater drain valve to flush the storage tank.
17.Flush the water heater storage tank to remove sediment and allow the water to flow until it runs clean.
18.Close the water heater drain valve when flushing is completed.
19.Remove the drain hose.
20.Fill the water heater - see Filling The Water Heater in this manual.
21.Turn on electrical supply to place water heater back in operation.
22.Allow the water heater to complete several heating cycles to ensure it is operating properly.
33