TROUBLESHOOTING GUIDELINES
WATER HEATER CONTROL
TROUBLE SHOOTING
Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician.
Read the GENERAL SAFETY INFORMATION section first.
# | LED STATUS | PROBLEM | SOLUTION | |||
1 | B | C D | E | F | Inadequate or no earth ground | 1. Ensure the wall outlet is properly grounded. |
|
|
|
| sensed by the | 2. Ensure all ground connections/wires on the | |
|
|
|
|
| control. | |
|
|
|
|
|
| water heater are secure. |
2 | B | C D | E | F | Power supply to | 1. Ensure the wall outlet is properly wired. |
|
|
|
| control has reversed polarity or a | 2. Ensure all internal 120 VAC wiring connections and | |
|
|
|
|
| high resistance to earth ground. | |
|
|
|
|
|
| wiring harness have no reversed wires. 120 VAC |
|
|
|
|
|
| “hot” wire must connect to the on/off switch. |
|
|
|
|
|
| 3. Ensure the wall outlet is properly grounded. |
|
|
|
|
|
| 4. Ensure all ground connections/wires on the water |
|
|
|
|
|
| heater are secure. |
3 | B | C D | E | F | Pressure switch circuit remaining | 1. Ensure air pressure switch circuit wiring is correct |
closed for more than 5 seconds | and the air pressure switch is not jumpered. | |||||
|
|
|
|
| after heating cycle begins. | 2. Secure power to water heater, check continuity of air |
|
|
|
|
| Blower does not start. | |
|
|
|
|
| Service Note: | pressure switch contacts with wires disconnected. |
|
|
|
|
| A If pressure switch contacts show continuity (closed | |
|
|
|
|
| Disconnect power - disconnect one | |
|
|
|
|
| wire from the air pressure switch | circuit) replace the pressure switch. |
|
|
|
|
| or the vent temperature limit | B If pressure switch contacts are open and all wiring |
|
|
|
|
| switch. Turn power back on - | |
|
|
|
|
| blower should start. | is correct - turn the power off for |
|
|
|
|
|
| then on again to clear the error code - if the error |
|
|
|
|
|
| code persists replace the |
|
|
|
|
|
|
|
4 | B | C D | E | F | Pressure switch circuit remains open | 1. Ensure the blower is running - check for 120 VAC to |
longer than 5 seconds after the blower | the blower when the heating cycle begins, check the | |||||
|
|
|
|
| is energized. | wiring. If the control does not energize the blower - |
|
|
|
|
| Blower may run continuously in | replace the |
|
|
|
|
| start when energized - replace the blower assembly. | |
|
|
|
|
| this condition. | 2. Ensure the air pressure switch sensing tube is properly |
|
|
|
|
|
| |
|
|
|
|
|
| connected - not kinked or damaged. |
|
|
|
|
|
| 3. Check continuity of vent temperature limit switch - replace |
|
|
|
|
|
| switch if contacts remain open under 160ºF (71°C). |
|
|
|
|
| Service Note: | 4. Ensure the correct size of vent pipe (2”, 3”, 4”) was used |
|
|
|
|
| per installation manual for vent length. Ensure maximum | |
|
|
|
|
| To learn more about performing Air | number of elbows or equivalent feet of vent pipe has not |
|
|
|
|
| Pressure Switch tests visit our web | exceeded maximum limits. |
|
|
|
|
| site www.hotwater.com to download | 5. Ensure there are no obstructions in the vent pipe. |
|
|
|
|
| technical bulletin | |
|
|
|
|
| Switches. | 6. Check air pressure switch performance - check pressure |
|
|
|
|
|
| |
|
|
|
|
|
| with a digital manometer - check continuity of contacts. |
|
|
|
|
|
| (see service note in left column) If the switch proves |
|
|
|
|
|
| defective - replace the air pressure switch and or the |
|
|
|
|
|
| blower assembly as required. |
|
|
|
|
|
| 7. If air pressure switch performance test results prove |
|
|
|
|
|
| the air pressure switch is working properly and error |
|
|
|
|
|
| code 4 persists - replace the |
|
|
|
|
|
|
|
| B | C D | E | F | The | 1. Check wiring to the hot surface ignitor - replace ignitor |
5 | an open ignitor circuit. | assembly if wiring is damaged or worn. | ||||
|
|
|
|
| Service Note: | 2. Check ignitor assembly plug and the socket on the |
|
|
|
|
| The resistance (ohms) of a hot surface | |
|
|
|
|
| ignitor will increase over time. If the | ignitor assembly and/or control if necessary. |
|
|
|
|
| resistance at room temperature is near | 3. Check resistance of ignitor at room temperature 77ºF |
|
|
|
|
| 18.8 ohms - consider replacing the ignitor | |
|
|
|
|
| as a preventative measure. | (25°C) at the plug end. Replace ignitor if resistance |
|
|
|
|
|
| is not within 11.5 and 18.8 ohms at room temperature. |
|
|
|
|
|
| 4. If results from the above tests were good and error |
|
|
|
|
|
| code 5 persists - replace the |
|
|
|
|
|
|
|