1.0 INTRODUCTION
1.1 Specifications
TABLE 1
ITEM | NATURAL GAS (NG) | PROPANE (LPG) | |||
INPUT: Hi | 32,500 Btu/hr | (9.5 kW) | 27,000 Btu/hr | (7.9 kW) | |
INPUT: Lo | 22,500 Btu/hr | (6.6 kW) | 21,000 Btu/hr | (6.2 kW) | |
MANIFOLD PRESSURE: Hi | 3.5” w.c. (0.82kPa) | 10.0” w.c. (2.49kPa) | |||
MANIFOLD PRESSURE: Lo | 1.7” w.c. (0.42kPa) | 6.3” w.c. (1.37kPa) | |||
GAS INLET SUPPLY | Minimum: 5.0” w.c. (1.25 kPa) | Minimum: 11” w.c. (2.74 kPa) | |||
PRESSURE: | Maximum: 10.5” w.c. (1.74 kPa) | Maximum: 13” w.c. (3.24 kPa) | |||
ORIFICE SIZE: @ | 2 x #57 DMS (2 x 0.043”) | 7/64“ (0.109”) | |||
AIR SHUTTER OPENING | *Completely open | Completely open* | |||
CONTROL VALVE TYPE: | Honeywell or SIT 820 Nova | Honeywell or SIT 820 | |||
VENTING | Simpson | Simpson | |||
| Security Secure Vent | Security Secure Vent | |||
Combustion efficiency (fan off) | 70.7% | 68.7% | |||
on maximum | |||||
|
|
|
| ||
Combustion efficiency (fan on) | 73.3% | 72.3% | |||
on maximum | |||||
|
|
|
| ||
FAN | Variable Speed (120v / 60hz) | Variable Speed (120v / 60hz) |
*May vary (±25%) depending on the installations. Judgment of installer is required.
REGISTER YOU WARRANTY ONLINE
To receive full warranty coverage, you will need to show evidence of the date you purchased your stove. Keep your sales invoice. We also recommend that you register your warranty online at www.drolet.ca
Registering your warranty online will help us track rapidly the information we need on your stove.
This heating unit must serve as a supplementary heat source. An alternative heat source should be available in the home if needed. The manufacturer cannot be responsible for additional heating costs associated with the use of an alternative heat source.
It is highly recommended that the user buys this product from a retailer who can provide installation and maintenance advices.
3