1.2 Features
Ignition system:
Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter.
Gas control:
Gas control valve type:
Automatic millivolt powered combination convenience and on/off switch. The gas source.
gas control valve with variable flame control for valve does not require electricity from an external
Fan control:
Variable speed control:
For units equipped with a fan control, the knob controls the fan speed in connection with a heat sensitive switch which turns on when the heater reaches operating temperature. Turning the knob
Safety controls:
A safety switch will shut the system down in the event of any one of the following conditions: Incorrectly installed vent system
Blocked vent causing flue spillage
Flow reversal or sustained down draft situation
1.3 Intended use
This appliance is intended to be used as a free standing heater. With the exception of Massachusetts, the
1.4 General safety
The appliance must be properly connected to a venting system in accordance with local codes. This unit must not be connected to a chimney or flue serving any other appliance. It is equipped with a safety control system to protect against improper venting of flue products.
WARNING: Operation of this unit when not connected to a properly installed and
maintained venting system may result in carbon monoxide poisoning.
Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service technician. Provide adequate clearances around air openings, for combustion and ventilation air, and allow accessibility clearance for servicing and proper operation.
5