| III. Main burner will not light |
| A. Valve / Switches |
|
|
|
| |
|
|
| 1. | Valve control off | 1. | Turn to “ON” position |
| |
|
|
| 2. | Blockage at the burner (line, | 2. | Check and clean |
| |
|
|
|
| orifice, or ports) |
|
|
|
|
|
|
| 3. | Defective wall switch or | 3. | Conduct a continuity test or jumper wire |
| |
|
|
|
| thermostat |
| test and replace if defective |
| |
|
|
| 4. | Defective wiring or connections | 4. | Conduct a test with a jumper wire and |
| |
|
|
|
|
|
| repair as required |
| |
|
|
| 5. | Excessive length of thermostat | 5. | Reduce wire length to less than 100 feet or |
| |
|
|
|
| wire from valve to wall switch or |
| increase wire size |
| |
|
|
|
| thermostat |
|
|
|
|
|
|
| 6. | Wall switch or thermostat | 6. | Wire correctly |
| |
|
|
|
| incorrectly wired |
|
|
|
|
|
|
| 7. | Defective Valve | 7. | Turn valve and “ON/OFF” switch to the |
| |
|
|
|
|
|
| “ON” position. Check with millivolt meter |
| |
|
|
|
|
|
| at terminals |
| |
|
|
|
|
|
| should read greater then 460 millivolts. If |
| |
|
|
|
|
|
| the reading is OK and the burner does not |
| |
|
|
|
|
|
| come on, replace the gas valve |
| |
|
|
| 8. | Thermopile may not be | 8. | Recheck using the millivolt meter. The |
| |
|
|
|
| generating sufficient voltage |
| pilot flame may not be high enough for the |
| |
|
|
|
| (460 mV) |
| flame to properly engulf the thermopile. If |
| |
|
|
|
|
|
| so, adjust and reset. If voltage is still |
| |
|
|
|
|
|
| insufficient, replace thermopile |
| |
|
|
| 9. | Wall switch, thermostat, or wires | 9. | Follow previous corrective action, check |
| |
|
|
|
| are defective |
| switch and wiring. Replace where |
| |
|
|
|
|
|
| defective |
| |
|
|
|
|
|
|
|
| |
| IV. Soot deposits on glass |
| 1. Flame impingement on logs | 1. | Adjust the log set to avoid direct flame |
| ||
|
|
|
|
|
| impingement. Follow log placement |
| |
|
|
|
|
|
| instructions |
| |
|
|
| 2. | Improper primary air setting | 2. | Open aeration shutter more. |
| |
|
|
| 3. | Foreign material impeding | 3. | Ensure that no foreign material blocks |
| |
|
|
|
| burner |
| burner flame ports |
| |
|
|
| 4. | Air inlet blocked or restricted | 4. | Clean air inlets |
| |
|
|
| 5. | Vent system is restricted or | 5. | Check correct termination is used. |
| |
|
|
|
| inadequate |
|
|
|
|
|
|
|
|
|
|
| ||
| V. Flame burns blue and lifts |
| 1. Insufficient combustion air being | 1.Ensure that no foreign material blocks air |
| |||
| off burner |
|
| supplied |
| inlets and that the burner shutter is |
| |
|
|
| 2. | Manifold pressure set too high |
| correctly adjusted. Ensure the vent is |
| |
|
|
|
|
|
| adequate |
| |
|
|
| 3. | Vent system restricted | 2. | Check manifold pressure |
| |
|
|
|
|
| 3. | Check vent system |
| |
| VI. Flames impinge on firebox |
| 1. Vent system is restricted or | 1. | Correct flue as required |
| ||
| top |
|
| inadequate |
|
|
|
|
|
|
| 2. | Manifold pressure too high | 2. | Check manifold pressure as required |
|
26