Enviro 1700-V Insert, Venice Specifications, Air Control Rod 1200-V & 1700-V General Information

Page 10

Specifications

AIR CONTROL:

The air wash and pilot air (control the amount of air to the fire) are controlled by the rod located on the right side of the unit. To increase your air, pull the rod out and to decrease, push the rod in. All the units have a secondary air that flows through the tubes at the top of the firebox, just below the baffles.

Pull this control all the way out when first starting the stove. Once the fire has been established you may adjust this control to set the burn rate of the fire. If this damper is closed at first start-up, the fire will burn very slowly and could soot the appliance.

When shutting down the stove, fully open the air control. This allows the chimney temperatures to remain as high as possible for as long as possible. Cold chimney temperatures create creosote.

SPECIFICATIONS:

Increase air - pull rod out

Decrease air - push rod in

Figure 3: Air Control Rod.

Table 1: 1200-V & 1700-V General Information.

Model

1200 Insert

1700 Insert

 

 

 

Width x Depth

273⁄4” x 211⁄2”

273⁄4” x 26”

(705 mm x 546 mm)

(705 mm x 660 mm)

 

 

 

 

Height of body

191/16” (484 mm) or 199/16” (497 mm)

Fire box size

16.1” x 18.25” x 11.15”

20.65” x 18.25” x 11.95”

(depth x width x height)

(409 mm x 464 mm x 283 mm)

(525 mm x 464 mm x 304 mm)

 

 

 

Capacity

1.85 feet3

2.5 feet3 (0.0708 meter3)

(0.0526 meter3)

* Approximate heating area

800 - 1,500 feet2

1,000 - 2,200 feet2

(74.3 - 139.4 meter2)

(92.9 - 205.4 meter2)

**E.P.A. output rating

11,479 to 34,196 BTU/hour

9,425 to 31,780 BTU/hour

(3,361 to 10,013 watt)

(2,760 to 9,306 watt)

 

 

 

 

*Duration on low burn

6 -10 hours

8 - 12 hours

 

 

 

Weight with packaging

335 lb (151.95 Kg)

390 lb (176.90 Kg)

 

 

 

E.P.A. Emissions

3.3 grams/hour

4.48 grams/hour

(0.116 oz/hour)

(0.158 oz/hour)

 

 

 

 

Surround Panels

 

 

 

 

Standard (width x height)

461⁄8” x 28” (1171 mm x 711 mm)

 

 

Oversized (width x height)

461⁄8” x 331⁄8” (1171 mm x 843 mm)

 

 

 

 

Rating Label Location

Side of Unit; Behind Right Shroud

 

 

 

10

Image 10
Contents Venice Table of Contents Safety Precautions Operating Instructions First StartFuel Selection Building/Maintaining a FireHelpful advice on the correct way to start your fire For Maximum EfficiencyWhat type of wood is best to use as firewood? Why can’t I get the fire lit?What does dry, seasoned wood mean? What is draft? What can cause a poor draft?1700-V Air Flow Path Specifications Air Control Rod 1200-V & 1700-V General InformationType of protection Modified Clearance Masonry Zero Clearance Minimum Depth 18 457 mm 225/16 566mm 2615/16 684mm Installation Insert UnitFloor Cast Before starting this type of installation refer 3D of Dimensions needed from Fireplace Before starting this type of installation When replacing bricks, use only pumas type fire bricks Total BricksTube C Tube B Tube a Installation of C-Cast Ceramic Baffle Installation Removal of Face Rating Label Do not Remove this Label / NE PAS Enlever Cette ÉtiquetteParts List Reference # DescriptionParts Diagram Warranty Exclusions and Limitations Warranty Installation Data Sheet