Enviro Venice, 1700-V Insert, 1200-V Insert owner manual Safety Precautions

Page 3

Safety Precautions

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death. Be aware that local Codes and Regulations may override some items in this manual. Check with your local inspector.

If this appliance is not properly installed, operated and maintained, a serious house fire could result. Do not use any makeshift materials during installation, maintenance, or replacement.

Never place wood, paper, furniture, drapes or other combustible materials near the stove. Do not let children or pets touch it when it is hot.

Operate only with the door tightly closed and burn wood directly on the stove hearth. Do not operate if the door glass is broken or a gasket is missing or damaged. Do not alter the combustion air control valves. Dangerous overfiring could occur which could ignite creosote in the chimney or cause a house fire.

At least 12 square inches (77.4 cm2) of fresh outside air should be admitted into the room or directly to the stove through a 4 inch (10.16 cm) diameter pipe. For the stove to operate combustion-air must be supplied through either the bottom or the back of the pedestal.

Do not burn coal or charcoal as there is danger of carbon monoxide being produced. Do not use chemical fluids to start or re-fresh the fire. Do not burn garbage or flammable fluids such as gasoline, grease, naphtha or engine oil. Never let the stove become hot enough to get any part red or glowing red.

Burning wet, unseasoned wood could cause excessive creosote accumulation in the flue pipe. When ignited, it could cause a chimney fire that could result in a serious house fire.

Do not use grates, andirons or any other methods to support or raise the fire up off the hearth of the appliance.

This appliance is tested to ULC-S627 Standard for Space Heaters for Use with Solid Fuel, ULC-S628 Standard for Fireplace Inserts, & UL 1482 Standard for Safety for Solid-Fuel Type Room Heaters.

Both the 1200-V & 1700-V Fireplace Inserts are approved for installed into a zero-clearance fireplaces in the U.S. In Canada refer to local building or fire officials for restrictions and installation inspection

In Canada the existing chimney must be lined to the termination for all masonry installs.

IMPORTANT: The following must be done to ensure proper operation. Failure to do so will cause extreme overheating and possible personal injury or property damage:

• If an outside air supply has not been added to this appliance, please ensure that the 4” inch fresh air outlet on the back of the pedestal is removed.

3

Image 3
Contents Venice Table of Contents Safety Precautions First Start Operating InstructionsBuilding/Maintaining a Fire Fuel SelectionFor Maximum Efficiency Helpful advice on the correct way to start your fireWhy can’t I get the fire lit? What type of wood is best to use as firewood?What does dry, seasoned wood mean? What can cause a poor draft? What is draft?1700-V Air Flow Path Air Control Rod 1200-V & 1700-V General Information SpecificationsType of protection Modified Clearance Masonry Zero Clearance Minimum Depth 18 457 mm 225/16 566mm 2615/16 684mm Insert Unit InstallationFloor Cast Before starting this type of installation refer 3D of Dimensions needed from Fireplace Before starting this type of installation Total Bricks When replacing bricks, use only pumas type fire bricksTube C Tube B Tube a Installation of C-Cast Ceramic Baffle Installation Removal of Face Do not Remove this Label / NE PAS Enlever Cette Étiquette Rating LabelReference # Description Parts ListParts Diagram Warranty Exclusions and Limitations Warranty Installation Data Sheet