Specifications
CLEARANCES TO COMBUSTIBLES -
Table 5:
A | Minimum clearance to an unshielded side wall | 10” (254 mm) |
|
|
| |
B | Minimum clearance to an unshielded 8” (203 | 24” (610 mm) |
|
|
| |
| mm) mantel |
|
|
|
| |
|
|
| ���� |
|
| |
C | Minimum top facing (protruding 3⁄4” | [19 | 191⁄2” (495 mm) | � | � | |
| mm]) clearance |
| �������� | |||
| mm]) clearance |
|
| � |
| |
D | Minimum side facing (protruding 3⁄4” | [19 | 1” (25 mm) |
|
| � |
|
|
|
|
|
| |
E | † From front of door opening to edge of floor | USA 16” (406 mm) |
|
|
| |
| protection |
| CND 18” (450 mm) |
|
| � |
F | † From side/back of unit to edge of floor | USA 6” (152 mm) |
| � | ||
|
| |||||
| protection |
| CND 8” (200 mm) |
|
|
|
†FLOOR PROTECTION:
If unit is raised 0” - 2”
If unit is raised 2” - 8”
Table 6: Reduction in (B) Minimum Clearance from
Type of protection | Modified Clearance | |
A minimum of .013” (0.33mm) sheet metal spaced out 1” (25mm) by non- | 12” (305 mm) | |
combustible spacers. | ||
| ||
|
| |
Ceramic tiles, or eqivalent | 161⁄8” (408 mm) | |
supports and spaced out 1” (25mm) by | ||
| ||
|
| |
Ceramic tiles, or eqivalent |
| |
supports with a minimum of .013” (0.33mm) sheet metal spaced out 1” | 12” (305 mm) | |
(25mm) by |
| |
|
|
NOTES:
(1)Mantel protection must have at least 3” (75mm) edge clearance on all sides, except as provided in Note 4.
(2)If an adhesive is used to support
(3)Heat shield mounting hardware attached to combustible materials must be placed at the lateral extremities of the shield.
(4)Minimum clearance to unprotected walls and ceilings must be maintained.
Table 7:
| Masonry | Zero Clearance | |
|
|
| |
Minimum Depth | 18” (457 mm) | 181⁄2” (470 mm) | |
|
|
| |
Minimum Width at back of fireplace | 223⁄8” (568 mm) | 23” (584 mm) | |
|
|
| |
Minimum Width at front of fireplace | 27” (686 mm) | 271⁄4” (692 mm) | |
|
|
| |
Minimum Width at front of fireplace to include shroud | 333⁄4” (857 mm) | 34” (864 mm) | |
|
|
| |
Minimum Height | 191⁄4” (489 mm)** | 20” (508 mm) | |
or 193⁄4” (502 mm) | |||
|
| ||
|
|
|
**If the masonry lintel height is only 191⁄4” (489 mm) to 193⁄4” (502 mm) refer to INSTALLATION - MODIFICATIONS FOR
INSTALLATION WITH 191⁄4” (489 MM) HIGH LINTEL - INSERT
12