Installation

 

 

 

 

 

 

 

 

 

 

 

The flue collar is removable for installations

 

 

 

 

 

 

 

 

 

into fireplaces with low openings.

 

 

 

 

 

 

 

 

 

a)

Remove

the

rear two (2) secondary

 

 

 

 

 

 

 

 

 

 

air

tube

and

C-Cast Ceramic Baffles,

 

 

 

 

 

 

 

 

 

 

if

installed (see C-CASTCERAMIC BAFFLE

 

 

 

 

 

 

 

 

 

 

INSTALLATION). Remove the secondary air

 

 

 

 

 

 

 

 

 

 

tubes by placing a screwdriver (any style

 

 

 

 

 

 

 

 

 

 

except flat head) into one of the air holes

 

 

 

 

 

USA 16” (406 mm)

 

 

and tapping it with a hammer/mallet to

 

 

 

 

 

 

 

the left.

 

 

 

 

 

 

 

CND 18” (450 mm)

 

b)

Unscrew the two (2) nuts on top of the

 

 

 

 

Floor Protection

8"

 

 

 

 

 

(203 mm)

 

 

inside of the firebox, using a 9/16” wrench

 

Masonry Fireplace

 

Combustible Floor

 

 

 

or socket (see Figure 13). The Flue Collar

Figure 11: Insert Installation into existing fireplace without

 

Clamps will slide off the bolts.

 

 

 

 

hearth.

 

 

 

 

c)

Pull the removable flue collar off the top

 

 

 

 

 

 

 

 

 

 

of the unit.

 

 

 

 

 

 

 

 

 

 

d)

Attach the flue collar to the venting pipe

 

 

 

 

 

 

 

 

 

 

using sheet metal screws.

 

 

 

 

 

 

 

 

 

e)

Push the unit into place while trying to

 

 

 

 

 

 

 

 

 

 

keep the collar attached to venting close

 

 

 

 

 

 

 

 

 

 

to the opening on the top of the unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent pipe

 

 

 

 

 

USA 16” (406 mm)

 

 

 

 

 

 

 

 

 

 

 

CND 18” (450 mm)

 

 

 

 

 

Collar Puller

 

 

 

 

 

 

 

 

 

 

 

 

 

Masonry Fireplace

 

 

 

Combustible Floor

 

 

 

 

 

 

 

1" (25mm)

 

 

 

 

 

 

 

Removable

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-Combustible Board (K 0.84)

 

 

 

 

 

 

Flue Collar

Figure 12: Insert Installation into existing floor level

 

 

 

 

 

Gasket

 

 

masonry fireplace.

 

 

 

 

 

 

 

f)

Place the Collar Puller, over the two bolts of the Flue

 

 

 

 

 

Collar and pull it into place (see Figure 14). Ensure that

 

 

 

Firebox Top

 

the bolts are to the left and right of the hole. If they are

 

 

 

 

not, the front secondary air tube will need to be removed

 

 

 

Cut-away

 

 

 

 

 

 

in order to install or remove the C-Cast Ceramic Baffles.

 

 

 

 

g) Slide the Flue Collar Clamps and washers over the bolts,

 

 

 

 

 

and screw the nuts back onto the bolts.

 

 

 

 

 

 

Flue Collar Clamp

h) Re-install C-Cast Ceramic

Baffles and

the rear

two

 

 

 

 

 

 

Washer

 

(2)

secondary

air

tube

(see

C-CAST

CERAMIC

BAFFLE

 

 

 

 

 

 

 

Nut

 

INSTALLATION).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. There are four (4) leveling legs (shown in Figure 15), two

Figure 13: Attaching removable flue collar.

(2) on each side, one at the back and one at the front of the

unit. Adjust the legs using a 3⁄8” wrench to ensure the unit is

 

 

 

 

stable.

 

 

 

 

 

 

 

 

 

 

 

 

17

Image 17
Contents Venice Table of Contents Safety Precautions First Start Operating InstructionsBuilding/Maintaining a Fire Fuel SelectionFor Maximum Efficiency Helpful advice on the correct way to start your fireWhat does dry, seasoned wood mean? Why can’t I get the fire lit?What type of wood is best to use as firewood? What can cause a poor draft? What is draft?1700-V Air Flow Path Air Control Rod 1200-V & 1700-V General Information SpecificationsType of protection Modified Clearance Masonry Zero Clearance Minimum Depth 18 457 mm 225/16 566mm 2615/16 684mm Insert Unit InstallationFloor Cast Before starting this type of installation refer 3D of Dimensions needed from Fireplace Before starting this type of installation Total Bricks When replacing bricks, use only pumas type fire bricksTube C Tube B Tube a Installation of C-Cast Ceramic Baffle Installation Removal of Face Do not Remove this Label / NE PAS Enlever Cette Étiquette Rating LabelReference # Description Parts ListParts Diagram Warranty Exclusions and Limitations Warranty Installation Data Sheet