Installation

C-CAST CERAMIC BAFFLE INSTALLATION:

1.Slide the right C-Cast Ceramic Baffle in over the secondary air tubes at the top of the firebox. The tab must be on the top and pointing towards the center and the smooth side is to face down.

2.Hook the outside edge of the baffle over the top of the secondary air chamber. This will make room to for the installation of the left C-Cast Ceramic Baffle.

3.Slide the left C-Cast Ceramic Baffle in over the secondary air tubes. The tab must be on the bottom and pointing towards the center and the smooth side is to face down.

4.Pull the baffles together in the middle so the right tab rests on top of the left tab. Ensure the baffles are flush with the back and both sides of the firebox.

Note for insert models only: If the bolts on the flue collar are not to the left and right of the hole, the front secondary air tube will need to be removed in order to install or remove the C-Cast Ceramic Baffles. To remove the front secondary air tube place a screwdriver (any style except flat head) into one of the air holes and tapping it with a hammer/mallet to the left.

Right Ceramic Baffle

Left Ceramic Baffle

Figure 23: Installation of C-Cast Ceramic Baffle.

FAN WIRING DIAGRAMS:

This appliance, when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.

CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

DO oil the fan bearings regularly.

DO NOT cut or remove the grounding prong from the plug.

DO NOT route the power cord beneath the heater.

WARNING: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged into a properly grounded three-prong receptacle.

23

Image 23
Contents Venice Table of Contents Safety Precautions First Start Operating InstructionsBuilding/Maintaining a Fire Fuel SelectionFor Maximum Efficiency Helpful advice on the correct way to start your fireWhat does dry, seasoned wood mean? Why can’t I get the fire lit?What type of wood is best to use as firewood? What can cause a poor draft? What is draft?1700-V Air Flow Path Air Control Rod 1200-V & 1700-V General Information SpecificationsType of protection Modified Clearance Masonry Zero Clearance Minimum Depth 18 457 mm 225/16 566mm 2615/16 684mm Insert Unit InstallationFloor Cast Before starting this type of installation refer 3D of Dimensions needed from Fireplace Before starting this type of installation Total Bricks When replacing bricks, use only pumas type fire bricksTube C Tube B Tube a Installation of C-Cast Ceramic Baffle Installation Removal of Face Do not Remove this Label / NE PAS Enlever Cette Étiquette Rating LabelReference # Description Parts ListParts Diagram Warranty Exclusions and Limitations Warranty Installation Data Sheet