Enviro Venice, 1700-V Insert, 1200-V Insert Before starting this type of installation refer

Page 18

Installation

Figure 14: Removable flue collar in place.

4.Screw or nail the provided metal plate with the wording “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.” to the inside of the fireplace.

Leveling Legs

Figure 15: Leveling legs.

SURROUND PANEL SEALED INSTALLATION FOR USA ONLY:

Note: Though this is an allowable installation, we do not recommend it because of the possibility of poor draft, and therefore poor stove performance.

Before starting this type of installation refer

to INSTALLATION - MASONRY FIREPLACE INSTALLATION

-INSERT for additional information. For

clearances refer to SPECIFICATIONS - CLEARANCES TO COMBUSTIBLES - 1200-V INSERT and

SPECIFICATIONS - CLEARANCES TO COMBUSTIBLES -

1700-V INSERT.

1.Before the face plate is installed onto the unit, glue a 6” (150mm) wide R20 fiberglass insulation strip around the perimeter of the back of the panels using RTV silicon or stove gasket cement. When the face plate is installed onto the unit the insulation must overlaps the fireplace opening to form a seal between the masonry fireplace and the unit’s face plate. Let the silicon or cement dry.

2.To make the installation of the surround panel onto the unit easy have the unit 6” (150mm) out from the fireplace,

3.Push the insert into the fireplace, allowing the insulation to form a seal between the panels and the fireplace. Tuck any exposed insulation behind the face plate.

����� �� ��� ���� ���� �� ������������ ��

��������� ���� ������� ���� � �������

��������������� ���� �� �� ��� � ������� ��

��� ������ ����� �� �� �� ��� ������ ���� �����

���� ������� ��� ��� ���� ���������� ����

��� ��� ��������� �� ������� �������������

�������� ������������� ��� ���� ���������

�� ������� ��� �� ��� ������� �� ������ ��������

�� ��������

Damper Removed

or Fastened Open

Mantel

Insulation Around the

Back of the Face Plate

Surround Panel

USA 16” (406 mm)

CND 18” (450 mm)

Masonry Fireplace

Figure 16: Installation with Surround Sealed.

18

Image 18
Contents Venice Table of Contents Safety Precautions Operating Instructions First StartFuel Selection Building/Maintaining a FireHelpful advice on the correct way to start your fire For Maximum EfficiencyWhy can’t I get the fire lit? What type of wood is best to use as firewood?What does dry, seasoned wood mean? What is draft? What can cause a poor draft?1700-V Air Flow Path Specifications Air Control Rod 1200-V & 1700-V General InformationType of protection Modified Clearance Masonry Zero Clearance Minimum Depth 18 457 mm 225/16 566mm 2615/16 684mm Installation Insert UnitFloor Cast Before starting this type of installation refer 3D of Dimensions needed from Fireplace Before starting this type of installation When replacing bricks, use only pumas type fire bricks Total BricksTube C Tube B Tube a Installation of C-Cast Ceramic Baffle Installation Removal of Face Rating Label Do not Remove this Label / NE PAS Enlever Cette ÉtiquetteParts List Reference # DescriptionParts Diagram Warranty Exclusions and Limitations Warranty Installation Data Sheet