Installation

INSTALLATION OF FIREPLACE INSERT PEDESTAL AND LEVELING LEGS:

There are two parts to the Meridian insert pedestal and they can be found

 

inside the hopper. Place unit on its’ back. Two hex head screws are used

 

on each side of the pedestal (refer to figure on right). Using a 5/16

 

wrench or socket attach the pedestal to the bottom of the unit.

 

OPTIONAL:

 

There are two leveling legs and they can be found

 

inside the manual bag. Each leveling leg consists of

 

a long bolt, a hex nut, a washer, and a square bolt

 

with clip (shown to left). For installation of the leveling

 

legs the unit should be on its’ back and a 1⁄2” wrench

 

is required for adjustments.

 

Install the square bolts into the square holes in the back corners of the

 

bottom. The square bolt should be inserted from inside the unit so that

 

the clip will be facing up.

Leveling Legs

Thread hex nut onto the bolt till it is approximately 1” (2.5cm) from the bolt head, slide washer onto bolt. Thread the bolt into the square nut so length of the bolt shown is the approximately height needed for leveling. When the unit is up right and the bolts can be adjusted to the exact height required. To lock the bolts at a height tighten the hex nut and washer against the square bolt

INSTALLING HOPPER COVER AND ADJUSTING HOPPER HEIGHT:

The hopper cover initially comes upside-down on top of the hopper. To install the hopper cover flip the cover over and fasten in place with four T20 screws shown in bottom left figure.

The back height of this unit can be set to one of three heights; 19” (48.3cm), 211⁄8” (53.7cm), 221⁄4” (56.5cm). The hopper should be set to the maximum height that can be used in the installation.

To change the height of the hopper back up or down, remove the seven T20 screws, three on each side and one on the back. The screw placement is shown in bottom right figure. Move the hopper assembly to the required setting and replace the screws. When the hopper back is in place it is recommended that silicone is used to seal the bottom lip of the hopper back and sides

25

Image 25
Contents Meridian Table of Contents Introduction Safety Warnings and Recommendations Important Safety DataCombustion. See Operation Slider/Damper Setting Rating Label LocationKeep ASH PAN Free of RAW Fuel Operating Instructions Automatic Safety FeaturesStove Controls Thermostat Installation Special Notes SLIDER/DAMPER SettingComponents more clearly Operating Your Pellet Stove Thermostat / Switch ModeDo not Operate the Unit with the Door or ASH PAN Ajar Turning Your Pellet Stove OFFTools Required to Clean Unit Routine Cleaning and MaintenanceDo not Place Unburned or RAW Pellet Fuel in ASH PAN Door Glass Post Season CLEAN-UPDeciding Where to Locate Your Pellet Appliance InstallationRemoving Your Pellet Appliance from the Pallet Floor Protection Freestanding Dimensions WidthHeight DepthBack Wall to Unit 3 inches Insert DimensionsVent Termination Requirements Outside Fresh AIR Connection Mobile Home InstallationFreestanding Insert Straight Through the Wall Through Wall InstallationThrough Wall with Vertical Rise Installations Straight Through Wall InstallationsVertical Installation Hearth Mount Installation Included in the Exterior Mounted Exhaust Blower KIT are Exterior Mounted Exhaust BlowerTo Supply Power to the Exhaust Blower Through Wall Vertical Installation Masonry Fireplace Insert Installation Installing Hopper Cover and Adjusting Hopper Height Installation of Fireplace Insert Pedestal and Leveling LegsRemoval Assembly and Installation of Insert Surround PanelsQuantity Description Plated Trim InstallationRight cab side with upper and lower cabinet trims Top front with top trimDoor with louvers Plated Door InstallationInner side of Meridian door Do not TroubleshootingWhat to do if Exhaust motor will not function normally Auger light flashes but auger motor does not turn at all Wiring Diagram Part Description Number Parts ListMeridian DiagramFreestandingSteelPartsInsert Steel Parts DiagramMeridian ComponentsDiagramPartsTo the Dealer WarrantyTo the Distributor Name of Owner Address Installation Data Sheet

C-10135 specifications

Enviro C-10135 is a cutting-edge solution that has emerged to address the growing concerns in environmental management and sustainability. Designed to meet the demands of modern industries, it incorporates a wide array of features and technologies that set it apart in the field.

One of the standout characteristics of Enviro C-10135 is its innovative waste management capabilities. The system employs advanced sorting and recycling technologies that enable efficient separation of contaminants from recyclable materials. This not only streamlines the recycling process but also significantly reduces the volume of waste sent to landfills. With a focus on circular economy principles, Enviro C-10135 helps industries adopt more sustainable practices while minimizing their environmental footprint.

The technology behind Enviro C-10135 is grounded in real-time data analytics. Integrated sensors monitor environmental conditions and waste composition continuously. This data is processed using advanced algorithms that provide actionable insights for waste management strategies. As a result, users can optimize operational efficiency, reduce costs, and enhance compliance with regulatory requirements.

Another key feature of Enviro C-10135 is its adaptability. The system can be customized to fit the specific needs of various industries, ranging from manufacturing to hospitality. Manufacturers can modify its settings to handle different types of waste, while facilities in the hospitality sector benefit from tailored solutions for food waste and packaging materials. This versatility makes Enviro C-10135 an attractive choice for businesses of all sizes.

Energy efficiency is also a salient characteristic of the Enviro C-10135. The system is engineered to minimize power consumption without compromising performance. It employs energy recovery technologies that harness excess energy generated during waste processing, which can be redirected for operational needs. This aspect not only lowers operational costs but also contributes to sustainability goals.

In addition to its technological prowess, Enviro C-10135 is user-friendly. The interface is designed to provide intuitive navigation for operators, easing the learning curve and ensuring efficient operation. Training programs and support are also available to assist users in maximizing the system's potential.

In summary, Enviro C-10135 is at the forefront of environmental technology, offering advanced waste management features, real-time monitoring and analytics, adaptability for various applications, energy efficiency, and user-friendly operation. As industries strive to meet sustainability targets, Enviro C-10135 stands as a vital asset in achieving these goals and fostering a cleaner, more sustainable future.