Enviro C-10135 owner manual SLIDER/DAMPER Setting, Special Notes, Components more clearly

Page 8

Operating Instructions

SLIDER/DAMPER SETTING:

THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION.

A Qualified Service Technician or Installer must set the Slider Damper.

The slider damper should be set only on a hot stove (operating for 30 minutes or more) by placing a Magnahelic Pressure Gauge in the firebox (test port is located in the center of the stove just below the door opening). Set the slider damper so that the pressure reads

0.11” w.c. (.028 KPa) on HIGH HEAT LEVEL and when turned down to

LOW HEAT LEVEL, a 0.07” to 0.11”w.c. (0.018 to 0.028 KPa) reading should be achieved

Exhaust Blower

Exhaust

Channel

Slider

Damper

Note: Some parts have been removed in order to see

components more clearly.

The pressure readings are taken through a hole in the front of the firebox under the door, using a Magnehelic Gauge.

The slider damper is located behind the left cab side. The door must be open for the cab side to be removed on all models. On freestanding model loosen the two T20 torx screws, one above and one below hinge, swing open left panel to access. On insert model remove the two T20 torx screws on the front, one above and one below hinge, and the one T20 at the top of the cab side under the top front.

If the fire goes out and the heat output has been set on the lowest setting, use the auger trim button to increase feed rate or the Slider Damper should be pushed in slightly, decreasing the air in the firebox. Check the firebox vacuum and re-set if necessary.

If after long periods of burning the fire builds up and over flows the burn pot or there is a build up of clinkers This would be a sign that the pellet quality is poor and the slider damper must be pulled to compensate, to give the fire more air.

The easiest way to make sure that an efficient flame is achieved is to see the characteristics of the fire.

A tall and lazy flame with dark orange tips requires more air – Open slider.

A short and brisk flame, like a blowtorch, has too much air – Close slider.

If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame then the air may be correct for proper operation - monitor for build up.

SPECIAL NOTES:

Pellet quality is a major factor in how the pellet stove will operate. If the pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up). If this happens, pull the Slider Damper out slightly to increase the air flow to the fire.

8

Image 8
Contents Meridian Table of Contents Introduction Important Safety Data Safety Warnings and RecommendationsCombustion. See Operation Slider/Damper Setting Rating Label LocationKeep ASH PAN Free of RAW Fuel Stove Controls Automatic Safety FeaturesOperating Instructions Thermostat Installation Components more clearly SLIDER/DAMPER SettingSpecial Notes Thermostat / Switch Mode Operating Your Pellet StoveDo not Operate the Unit with the Door or ASH PAN Ajar Turning Your Pellet Stove OFFDo not Place Unburned or RAW Pellet Fuel in ASH PAN Routine Cleaning and MaintenanceTools Required to Clean Unit Post Season CLEAN-UP Door GlassRemoving Your Pellet Appliance from the Pallet InstallationDeciding Where to Locate Your Pellet Appliance Freestanding Dimensions Width Floor ProtectionHeight DepthInsert Dimensions Back Wall to Unit 3 inchesVent Termination Requirements Freestanding Insert Mobile Home InstallationOutside Fresh AIR Connection Through Wall Installation Straight Through the WallStraight Through Wall Installations Through Wall with Vertical Rise InstallationsVertical Installation Hearth Mount Installation Exterior Mounted Exhaust Blower Included in the Exterior Mounted Exhaust Blower KIT areTo Supply Power to the Exhaust Blower Through Wall Vertical Installation Masonry Fireplace Insert Installation Installation of Fireplace Insert Pedestal and Leveling Legs Installing Hopper Cover and Adjusting Hopper HeightAssembly and Installation of Insert Surround Panels RemovalPlated Trim Installation Quantity DescriptionRight cab side with upper and lower cabinet trims Top front with top trimInner side of Meridian door Plated Door InstallationDoor with louvers What to do if TroubleshootingDo not Exhaust motor will not function normally Auger light flashes but auger motor does not turn at all Wiring Diagram Parts List Part Description NumberDiagramFreestandingSteelParts MeridianParts Diagram Insert SteelComponentsDiagramParts MeridianTo the Distributor WarrantyTo the Dealer Installation Data Sheet Name of Owner Address

C-10135 specifications

Enviro C-10135 is a cutting-edge solution that has emerged to address the growing concerns in environmental management and sustainability. Designed to meet the demands of modern industries, it incorporates a wide array of features and technologies that set it apart in the field.

One of the standout characteristics of Enviro C-10135 is its innovative waste management capabilities. The system employs advanced sorting and recycling technologies that enable efficient separation of contaminants from recyclable materials. This not only streamlines the recycling process but also significantly reduces the volume of waste sent to landfills. With a focus on circular economy principles, Enviro C-10135 helps industries adopt more sustainable practices while minimizing their environmental footprint.

The technology behind Enviro C-10135 is grounded in real-time data analytics. Integrated sensors monitor environmental conditions and waste composition continuously. This data is processed using advanced algorithms that provide actionable insights for waste management strategies. As a result, users can optimize operational efficiency, reduce costs, and enhance compliance with regulatory requirements.

Another key feature of Enviro C-10135 is its adaptability. The system can be customized to fit the specific needs of various industries, ranging from manufacturing to hospitality. Manufacturers can modify its settings to handle different types of waste, while facilities in the hospitality sector benefit from tailored solutions for food waste and packaging materials. This versatility makes Enviro C-10135 an attractive choice for businesses of all sizes.

Energy efficiency is also a salient characteristic of the Enviro C-10135. The system is engineered to minimize power consumption without compromising performance. It employs energy recovery technologies that harness excess energy generated during waste processing, which can be redirected for operational needs. This aspect not only lowers operational costs but also contributes to sustainability goals.

In addition to its technological prowess, Enviro C-10135 is user-friendly. The interface is designed to provide intuitive navigation for operators, easing the learning curve and ensuring efficient operation. Training programs and support are also available to assist users in maximizing the system's potential.

In summary, Enviro C-10135 is at the forefront of environmental technology, offering advanced waste management features, real-time monitoring and analytics, adaptability for various applications, energy efficiency, and user-friendly operation. As industries strive to meet sustainability targets, Enviro C-10135 stands as a vital asset in achieving these goals and fostering a cleaner, more sustainable future.