MAINTENANCE AND TECHNICAL
Annually check to ensure that your Vent system is clear.
Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with small yellow tips.
CLEANING OF GLASS
Do not clean glass when hot
It will be necessary to clean the ceramic glass periodically. During a cold start up, condensation will sometimes form on the glass, this is a normal condition with all gas fireplaces and stoves. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first two weeks of use.
After that, depending upon the amount of use, cleaning should be required no more than two or three times per season.
To clean the door, use a mild glass cleaner and a soft cloth. Abrasive cleaners will damage the glass and gold surfaces.
OPENING THE DOOR
Turn unit off and wait until the appliance has cooled down.
1.Open the right hand hinged side flap, which will expose a door fastener. Using a 1/2" wrench, loosen the fastener.
2.Due to the shape of the bay window door. You must also open the
3.Ensure the door is properly fastened after cleaning before attempting to
TO REPLACE DOOR AND GLASS ASSEMBLY
The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a replacement door assembly including glass must be fitted.
To Replace:
•open door fully
•Lift door vertically so that hinge pins lift out of hinge receivers.
•Return the door assembly to dealer.
Door and glass assembly must be replaced as a complete unit by your ENVIROGAS Dealer.
No substitute materials are allowed.
Use extreme caution cleaning up broken glass. Use thick gloves and broom to brush glass up.
FOR CLEANING THE INSIDE OF THE FIREBOX
Remove the log carefully from the firebox. Gently remove the embers and place on a piece of paper towel. Until ready to replace.
Vacuum the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner.
After carefully replacing the log and embers in their correct positions, and the door has been resealed,
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE