Enviro EG 40 B Operating Instructions, Lighting Instructions, What to do if YOU Smell GAS

Page 9

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A)This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly.

B)BEFORE LIGHTING smell all around the appliance

area for gas, and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it . Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Turn off all electrical power to the appliance.

3. Turn the gas control knob clockwise to the “off’ position.

4.Open door. Wait five (5) minutes to clear out any gas. Close door. If you smell gas including near the floor, STOP! Follow “B” in the above safety information.

If you don’t smell gas go to next step.

5.Find the pilot located to the right between the front and rear burner.

6. Turn gas control knob counter-clockwise to “PILOT”.

7.Push the gas control knob in fully and hold. Immediately light the pilot by pushing the piezo spark igniter. Keep knob depressed for about 30 seconds after pilot is lit. Release knob. If pilot goes

out, repeat steps 4 through 6.

WARNING The gas valve has a lockout device, which will not allow the pilot burner to be re-lit until the thermocouple, has cooled.

If the knob does not pop up when released, stop and immediately call your service technician or gas

supplier.

NOTE: Check to be sure the pilot flame engulfs the thermocouple and that the burners light

completely.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF" and call you service technician or gas supplier.

8. Turn gas control knob counter-

clockwise to the “ON” position.

Flip burn

HI \ LO knob Control knob

er switch to “ON” then turn “HI / LO” knob to the desired setting.

9. Turn on all electrical power to the unit

TO TURN OFF GAS TO

1. Turn the gas control knob clockwise to “OFF” DO NOT FORCE

APPLIANCE

2.Turn off all electrical power to the appliance if service is to be performed.

3.Flip burner switch to off.

9

Image 9
Contents For Your Safety What to do if YOU Smell GASS H E R W O O D I N D U S T R I E S L T D Safety Precautions For Your SafetyGeneral Table of Contents Assembly InstructionsCode Approvals Deciding Where to Locate Your Stove DimensionsClearances Vent Terminal Clearances Venting Flue GAS Spill SwitchManufacturers General Venting Guidelines Using AN Existing ChimneyInstalling the Glowing Embers Installation of LOG SET and EmbersOperating Instructions For Your Safety Read Before OperatingLighting Instructions What to do if YOU Smell GASCleaning of Glass Maintenance and TechnicalTo Replace Door and Glass Assembly For Cleaning the Inside of the FireboxProblem Possible Cause Solution Trouble ShootingNever USE AN Open Flame for Leak Testing GAS Line ConnectionOrifice SIZES, Pressure and BTU’S Electrical Installing Remote Thermostat or Wall SwitchService Parts available from your local Envirogas Dealer Parts and AccessoriesFuel Type Conversion To a Maximum of Seven Years WarrantyTo the Dealer To the DistributorParts List EG 40 Door and Burner Assemblies EC-031 GasketExploded EG 40 Freestanding Model EG Installation Data Sheet