Enviro EG 40 B owner manual Deciding Where to Locate Your Stove, Dimensions, Clearances

Page 4

DECIDING WHERE TO LOCATE YOUR STOVE

DIMENSIONS:

Front Width:

25"/ 63 cm

Rear Width:

25"/ 63 cm

Height:

29"/

74 cm*

Depth

21"/

53 cm

( *not including vent coupling ) Shipping Weight: 256 lbs/116 kg

CLEARANCES:

FIG. 1

A. Side wall to stove

12"/ 30cm

B. Rear wall to stove

4"/ 10cm

C. Combustible to stove Top

36”/ 91cm

D. Floor to stove

0"/ 0cm

E. Corner clearance

2"/ 5cm

F. Alcove depth

48"/ 122cm

Maintain sufficient clearances

 

for service and maintenance

 

FIG. 2

The stove should be located out of traffic and away from furniture and draperies.

The stove should have sufficient access for its safe operation and maintenance.

Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building. e.g. cutting a wall or ceiling joist.

The stove can be installed on any standard flooring materials. i.e. Wood, carpet or linoleum.

Check stove and flue system clearance requirements.

Locate the stove where it can be accessed by a gas supply line.

Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.

As the stove is equipped with a convection fan, ensure that an electrical outlet is within 6ft. (1.8m) of the stove.

These stoves can be installed in bedrooms.

(IN CANADA: must be installed with a listed wall thermostat)

(IN USA: see current ANSI Z223.1 for installation instructions.)

The flow of combustion and ventilation air must not be obstructed.

4

Image 4 Contents
What to do if YOU Smell GAS For Your SafetyS H E R W O O D I N D U S T R I E S L T D For Your Safety Safety PrecautionsGeneral Assembly Instructions Table of ContentsCode Approvals Dimensions Deciding Where to Locate Your StoveClearances Vent Terminal Clearances Flue GAS Spill Switch VentingUsing AN Existing Chimney Manufacturers General Venting GuidelinesInstallation of LOG SET and Embers Installing the Glowing EmbersFor Your Safety Read Before Operating Operating InstructionsLighting Instructions What to do if YOU Smell GASMaintenance and Technical Cleaning of GlassTo Replace Door and Glass Assembly For Cleaning the Inside of the FireboxTrouble Shooting Problem Possible Cause SolutionGAS Line Connection Never USE AN Open Flame for Leak TestingOrifice SIZES, Pressure and BTU’S Installing Remote Thermostat or Wall Switch ElectricalParts and Accessories Service Parts available from your local Envirogas DealerFuel Type Conversion Warranty To a Maximum of Seven YearsTo the Dealer To the DistributorParts List EC-031 Gasket EG 40 Door and Burner AssembliesExploded EG 40 Freestanding Installation Data Sheet Model EG