ELECTRICAL
The ENVIROGAS EG 40.FS.BV. will operate with no external power supply. These models have a Milli volt gas control which uses the pilot flame to generate enough electricity to operate the main burner.
The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.
NOTE:
•Operation of the fan increases the efficiency and the heat output of the appliance.
•The thermostat connects to the two purple wires in the harness
•Control panel light uses a 7w Max. bulb
CAUTION
Label all wires
prior to
disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS. This appliance is equipped with a
DO NOT cut or remove the grounding prong from the plug.
INSTALLING REMOTE THERMOSTAT OR WALL SWITCH
RECOMMENDED WIRE SIZE for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire)
1.Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch.
2.Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. Use the terminals marked (TP/TH and TH).
RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE)
WHEN USING WALL THERMOSTAT
WIRE SIZE | MAXIMUM LENGTH |
14 GAUGE | 100 FEET |
16 GAUGE | 64 FEET |
18 GAUGE | 40 FEET |
20 GAUGE | 18 FEET |